SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:6453e8dd-59ca-4289-ab50-7759c182e49b"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:6453e8dd-59ca-4289-ab50-7759c182e49b" > Quantifying the opt...

  • Pham, T. H (författare)

Quantifying the optical properties and chromophore concentrations of turbid media by chemometric analysis of hyperspectral diffuse reflectance data collected using a fourier interferometric imaging system

  • Artikel/kapitelEngelska2001

Förlag, utgivningsår, omfång ...

  • 2016-08-31
  • SAGE Publications,2001
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:6453e8dd-59ca-4289-ab50-7759c182e49b
  • https://lup.lub.lu.se/record/2259161URI
  • https://doi.org/10.1366/0003702011952938DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • A non-contact Fourier transform interferometric imaging system was used to collect hyperspectral images of the steady-state diffuse reflectance from a point source in turbid media for the spectral range of 550-850 nm. Steady-state diffuse reflectance profiles were generated from the hyperspectral images, and partial least-squares (PLS) regression was performed on the diffuse reflectance profiles to quantify absorption (mu (alpha)) and reduced scattering (mu (s)') properties of turbid media. The feasibility of using PLS regression to predict optical properties was examined for two different sets of spatially-resolved diffuse reflectance data. One set of data was collected from 40 turbid phantoms, while the second set was generated by convolving Monte Carlo simulations with the instrument response of the imaging system. Study results show that PLS prediction of mu (alpha) and mu (s)' was accurate to within +/-8% and +/-5%, respectively, when the model was trained on turbid phantom data. Moreover, PLS prediction of optical properties was considerably faster and more efficient than direct least-squares fitting of spatially-resolved profiles. When the PLS model was trained on Monte Carlo simulated data and subsequently used to predict mu (alpha) and mu (s)' from the diffuse reflectance of turbid phantom, the percent accuracies degraded to +/-12% and +/-5%, respectively. These accuracy values are applicable to homogenous, semi-infinite turbid phantoms with optical property ranges comparable to tissues.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Eker, C (författare)
  • Durkin, A (författare)
  • Tromberg, B. J (författare)
  • Andersson-Engels, StefanLund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)fysi-san (författare)
  • AtomfysikFysiska institutionen (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Applied Spectroscopy: SAGE Publications55:8, s. 1035-10451943-35300003-7028

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Pham, T. H
Eker, C
Durkin, A
Tromberg, B. J
Andersson-Engels ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Atom och molekyl ...
Artiklar i publikationen
Applied Spectros ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy