SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Lammertsma Adriaan A)
 

Search: WFRF:(Lammertsma Adriaan A) > (2015-2019) > A novel partial vol...

A novel partial volume correction method for accurate quantification of [18F] flortaucipir in the hippocampus

Wolters, Emma E. (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
Golla, Sandeep S.V. (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
Timmers, Tessa (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
show more...
Ossenkoppele, Rik (author)
Lund University,Lunds universitet,Klinisk minnesforskning,Forskargrupper vid Lunds universitet,Clinical Memory Research,Lund University Research Groups,Amsterdam UMC - Vrije Universiteit Amsterdam
van der Weijden, Chris W.J. (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
Scheltens, Philip (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
Schwarte, Lothar (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
Schuit, Robert C. (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
Windhorst, Albert D. (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
Barkhof, Frederik (author)
Amsterdam UMC - Vrije Universiteit Amsterdam,University College London
Yaqub, Maqsood (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
Lammertsma, Adriaan A. (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
Boellaard, Ronald (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
van Berckel, Bart N.M. (author)
Amsterdam UMC - Vrije Universiteit Amsterdam
show less...
 (creator_code:org_t)
2018-08-15
2018
English.
In: EJNMMI Research. - : Springer Science and Business Media LLC. - 2191-219X. ; 8
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: Off-target binding in the choroid plexus (CP) may cause spill-in of the tau PET tracer [18F] flortaucipir into the adjacent hippocampus region. The impact of this spill-in on hippocampal uptake was assessed using a novel partial volume correction method (PVC). Methods: PVC was performed on 20 [18F] flortaucipir dynamic PET scans (10 probable AD and 10 controls). Volumes of interest (VOIs) were defined for both hippocampus and CP. The correlation between hippocampal and CP distribution volume (VT), with and without PVC, was determined. Both anatomically defined and eroded VOIs were used. Results: For controls, the correlation between hippocampal and CP VT was significantly reduced after using PVC along with an eroded VOI (r2 = 0.59, slope = 0.80 versus r2 = 0.15, slope = 0.15; difference: p < 0.05). The same was true for AD patients (p < 0.05). Conclusion: PVC together with an optimized hippocampal VOI resulted in effective reduction of CP spill-in and improved accuracy of hippocampal VT.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view