SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:67d227a8-2ac1-46a6-9fe1-80eec7d8dd4f"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:67d227a8-2ac1-46a6-9fe1-80eec7d8dd4f" > Diurnal variations ...

Diurnal variations of the dominant cycle length of chronic atrial fibrillation

Meurling, Carl (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Waktare, J E (författare)
Holmqvist, Fredrik (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Hedman, A (författare)
Camm, A J (författare)
Olsson, Bertil (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Malik, M (författare)
visa färre...
 (creator_code:org_t)
2001
2001
Engelska.
Ingår i: American Journal of Physiology: Heart and Circulatory Physiology. - 1522-1539. ; 280:1, s. 401-406
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • High-resolution digital Holter recording was carried out in 21 patients (15 men, 64 +/- 12 yr) with chronic atrial fibrillation. Dominating atrial cycle length (DACL) was derived by frequency domain analysis of QRST-reduced electrocardiograms. Daytime mean DACL was 150 +/- 17 ms, and nighttime mean was 157 +/- 22 ms (P = 0. 0002). Diurnal fluctuation in DACL differed among patients: it tended to be virtually absent in those with a short mean DACL, but in those with longer DACL the night-day difference was as much as 23 ms (R = 0.72, P < 0.001, correlation of mean DACL to night-day difference). Mean DACL also correlated with ventricular cycle length (R = 0.40, P < 0.001), particularly at night (r = 0.49). The shorter cycle lengths found in this study during the day are consistent with sympathetic and/or other physiological modulation, but since increased vagal tone shortens atrial refractoriness in most models, parasympathetic influences are not likely to play a major role. Alternatively, atrial effective refractory period may not be the sole determinant of atrial cycle length during atrial fibrillation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy