SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0039 9140 OR L773:1873 3573
 

Sökning: L773:0039 9140 OR L773:1873 3573 > Optimization of dis...

Optimization of dispersive liquid-liquid microextraction of copper (II) by atomic absorption spectrometry as its oxinate chelate: Application to determination of copper in different water samples

Farajzadeh, Mir Ali (författare)
Bahram, Morteza (författare)
Mehr, Behzad Ghorbani (författare)
visa fler...
Jönsson, Jan Åke (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Elsevier BV, 2008
2008
Engelska.
Ingår i: Talanta. - : Elsevier BV. - 1873-3573 .- 0039-9140. ; 75:3, s. 832-840
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study a dispersive liquid-liquid microextraction (DLLME) method based on the dispersion of an extraction solvent into aqueous phase in the presence of a dispersive solvent was investigated for the preconcentration of Cu2+ ions. 8-Hydroxy quinoline was used as a chelating agent prior to extraction. Flame atomic absorption spectrometry using an acetylene-air flame was used for quantitation of the analyte after preconcentration. The effect of various experimental parameters on the extraction was investigated using two optimization methods, one variable at a time and central composite design. The experimental design was performed at five levels of the operating parameters. Nearly the same results for optimization were obtained using both methods: sample size 5 mL; volume of dispersive solvent 1.5 mL; dispersive solvent methanol; extracting solvent chloroform; extracting solvent volume 250 mu L; 8-hydroxy quinoline concentration and salt amount do not affect significantly the extraction. Under the optimum conditions the calibration graph was linear over the range 50-2000 mu g L-1. The relative standard deviation was 5.1% for six repeated determinations at a concentration of 500 mu g L-1. The limit of detection (S/N = 3) was 3 mu g L-1.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

central composite design
a time
one variable at
dispersive liquid-liquid microextraction
optimization
copper ion determination
atomic absorption spectrometry

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Talanta (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Farajzadeh, Mir ...
Bahram, Morteza
Mehr, Behzad Gho ...
Jönsson, Jan Åke
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Talanta
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy