SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Pahlm Olle)
 

Sökning: WFRF:(Pahlm Olle) > (2010-2014) > Comparison of two c...

  • Brudin, LarsLinköpings universitet,Avdelningen för kardiovaskulär medicin,Hälsouniversitetet (författare)

Comparison of two commonly used reference materials for exercise bicycle tests with a Swedish clinical database of patients with normal outcome

  • Artikel/kapitelEngelska2014

Förlag, utgivningsår, omfång ...

  • 2013-10-31
  • Wiley,2014

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:6bf072b4-864e-4633-810c-2d92acda225c
  • https://lup.lub.lu.se/record/4659340URI
  • https://doi.org/10.1111/cpf.12097DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-110492URI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:129566284URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • Funding Agencies|Swedish Heart Lung Foundation; Karolinska Institute
  • Background: Reference values for working capacity, blood pressure, heart rate, perceived exertion, etc. during bicycle exercise tests have been sought after for many years. This is because earlier commonly used reference values for physical work capacity have been either too low or too high when compared to the clinical experience of several Swedish departments of clinical physiology. The aim of the study was to compare two commonly used reference materials with normal outcomes from a clinical database. Methods: Data from a clinical database of standardized exercise tests in Kalmar, Sweden, between 2004 and 2012, and having been judged as normal, were divided into 5-year categories of 5-10 to 75-80 years of age covering people from 7 to 80 years of age. Results: Maximal working capacity (W-max), maximal heart rate, maximal systolic blood pressure and maximal perceived exertion are presented for each of the 15 age categories. Regression equations are also presented for each sex with age and height as independent predictors. Quantitative comparisons of W-max are calculated for the three materials and possible explanations discussed. Conclusions: Values of W-max lie between the two reference materials most commonly used in Sweden. In addition, the present material covers subjects aged 7-19 years.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Jorfeldt, L.Karolinska Institutet (författare)
  • Pahlm, OlleLund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital, Sweden(Swepub:lu)klfy-opa (författare)
  • Linköpings universitetAvdelningen för kardiovaskulär medicin (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Clinical Physiology and Functional Imaging: Wiley34:4, s. 297-3071475-09611475-097X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Brudin, Lars
Jorfeldt, L.
Pahlm, Olle
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Lunds universitet
Linköpings universitet
Karolinska Institutet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy