Structural analysis of slender glass panel subjected to static and impact loading

Kozłowski, Marcin (författare)
Lund University,Lunds universitet,Byggnadsmekanik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Structural Mechanics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH,Silesian University of Technology
Kinsella, David (författare)
Lund University,Lunds universitet,Byggnadsmekanik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Structural Mechanics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
Persson, Kent (författare)
Lund University,Lunds universitet,Byggnadsmekanik,Institutionen för byggvetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Structural Mechanics,Department of Construction Sciences,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Kubica, Jan (författare)
Silesian University of Technology
Hulimka, Jacek (författare)
Silesian University of Technology
Louter, Christian (redaktör/utgivare)
Bos, Freek (redaktör/utgivare)
Belis, Jan (redaktör/utgivare)
Veer, Fred (redaktör/utgivare)
Nijsse, Rob (redaktör/utgivare)
visa färre...
 (creator_code:org_t)
2018
2018
Engelska 8 s.
Ingår i: Challenging Glass 6 : Conference on Architectural and Structural Applications of Glass, CGC 2018 - Proceedings - Conference on Architectural and Structural Applications of Glass, CGC 2018 - Proceedings. - 9789463660440 ; , s. 427-434
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Slender glass panels are widely used as storefronts and indoor separating walls in shopping malls and public buildings. To ensure that the design and construction is technically safe for general use and that it meets current and accepted technical standards, in-situ testing is required by the building administrator or authorities. A case study was performed of an indoor glass lantern in a public building made from slender two-side supported glass panels with a complex geometry. It provides structural assessments and results of in-situ experiments including static loading and soft body impact test. Results from numerical simulations of impact loading on the glass panels complementing the experimental results are also presented. The in-situ testing proved that the structural design meets current standards regarding the static loading. The soft body impact test proved the safety of the intact panel and the panel with one ply deliberately broken. The numerical study showed that, for a more complicated geometry, the stress distribution can dramatically change over time and that stress concentrations can develop at certain locations at a late stage in the impact history.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Architectural glass
Glass
Impact loading
In-situ testing
Numerical simulations
Static loading

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy