SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:lup.lub.lu.se:700b6e91-ed82-4204-860a-0d0b4480dbf7"
 

Search: id:"swepub:oai:lup.lub.lu.se:700b6e91-ed82-4204-860a-0d0b4480dbf7" > Noncovalent antibod...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Yan, HongLund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH (author)

Noncovalent antibody immobilization on porous silicon combined with miniaturized Solid-Phase Extraction (SPE) for array based immunoMALDI assays

  • Article/chapterEnglish2011

Publisher, publication year, extent ...

  • 2011-05-18
  • American Chemical Society (ACS),2011

Numbers

  • LIBRIS-ID:oai:lup.lub.lu.se:700b6e91-ed82-4204-860a-0d0b4480dbf7
  • https://lup.lub.lu.se/record/1973099URI
  • https://doi.org/10.1021/ac200679tDOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:art swepub-publicationtype
  • Subject category:ref swepub-contenttype

Notes

  • This paper presents a new strategy to combine the power of antibody based capturing of target species in complex samples with the benefits of microfluidic reverse phase sample preparation on an integrated sample enrichment target (RP-ISET) and the analysis speed of MALDI MS. The immunoaffinity step is performed on an in-house developed 3D-structured high surface area porous silicon (PSi) matrix, which allows efficient antibody immobilization by surface adsorption without any coupling agents in 30-60 min. The hydrophilic nature of the porous silicon surface at the molecular level displays a low adsorption of background peptides when exposed to complex digests or plasma samples, improving the conditions for the antigen specific extraction and subsequent readout. At the same time, the hydrophobic behavior, due to the nanostructured surface, of the PSi material facilitates liquid confinement during the assay. Using a footprint conforming to the standard for 384 well microplates, direct adaption of the protocol into standard sample handling robots is possible. The performance of the proposed immunoaffinity PSi-ISET immunoMALDI (iMALDI) assay was evaluated by specific detection of angiotensin I at a 10 femtomol level in diluted plasma samples (10 μL, 1 nM).

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Ahmad Tajudin, AsilahLund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)elma-ala (author)
  • Bengtsson, MartinLund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)elma-mbe (author)
  • Xiao, Shoujun (author)
  • Laurell, ThomasLund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)elma-tla (author)
  • Ekström, SimonLund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)elma-sek (author)
  • Avdelningen för Biomedicinsk teknikInstitutionen för biomedicinsk teknik (creator_code:org_t)

Related titles

  • In:Analytical Chemistry: American Chemical Society (ACS)83, s. 4942-49481520-68820003-2700

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view