Ankle dorsiflexor muscle performance in healthy young men and women: reliability of eccentric peak torque and work measurements

Drake, Anna Maria (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
Porter, Michelle M (författare)
Faculty of Physical Education and Recreation Studies, University of Manitoba, Canada
Downham, David (författare)
Department of Mathematical Sciences, University of Liverpool, UK
visa fler...
Lexell, Jan (författare)
Lund University,Lunds universitet,Neurokirurgi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurosurgery,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine,Department of Rehabilitation, Lund University Hospital, Sweden
Holmbäck, Anna-Maria (författare)
Department of Physical Therapy, Lund University, Sweden
visa färre...
 (creator_code:org_t)
Medical Journals Sweden AB, 2001
2001
Engelska.
Ingår i: Journal of Rehabilitation Medicine. - : Medical Journals Sweden AB. - 1651-2081 .- 1650-1977. ; 33:2, s. 90-96
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aims of this study were: (i) to assess the test-retest intrarater reliability of eccentric ankle dorsiflexor muscle performance in young healthy men and women using the Biodex dynamometer; and (ii) to examine different statistical indices for the interpretation of reliability. Thirty men and women (age 22.5 +/- 2.5 years, mean +/- S.D.) performed three maximal eccentric contractions at 30 degrees/second and 90 degrees/second, with 7-10 days between test sessions. Reliability was evaluated with three intraclass correlation coefficients (ICC1,1, ICC2,1 and ICC3,1), and was excellent for peak torque (ICC 0.90-0.96) and good to excellent for work (ICC 0.69-0.83), with no discernible differences among the three ICCs. Method errors, assessed by the standard error of the measurement (S.E.M.) and S.E.M.%, were low. The Bland & Altman graphs and analyses indicated no significant systematic bias in the data. In conclusion, measurements of eccentric ankle dorsiflexor muscle performance in young healthy individuals using the Biodex are highly reliable.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Annan medicin och hälsovetenskap -- Övrig annan medicin och hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Other Medical and Health Sciences -- Other Medical and Health Sciences not elsewhere specified (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Idrottsvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Sport and Fitness Sciences (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy