SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Lewis Jennifer)
 

Search: WFRF:(Lewis Jennifer) > Rim Sign in Breast ...

Rim Sign in Breast Lesions on Diffusion-Weighted Magnetic Resonance Imaging: Diagnostic Accuracy and Clinical Usefulness

Kang, Bong Joo (author)
Lipson, Jafi Alyssa (author)
Planey, Katie RoseMary (author)
show more...
Zackrisson, Sophia (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Ikeda, Debra M. (author)
Kao, Jennifer (author)
Pal, Sunita (author)
Moran, Catherine J. (author)
Daniel, Bruce Lewis (author)
show less...
 (creator_code:org_t)
2014-03-03
2015
English.
In: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 41:3, s. 616-623
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • PurposeTo investigate the diagnostic accuracy and clinical usefulness of the rim sign in breast lesions observed in diffusion-weighted magnetic resonance imaging (DWI). Materials and MethodsThe magnetic resonance imaging (MRI) findings of 98 pathologically confirmed lesions (62 malignant and 36 benign) in 84 patients were included. Five breast radiologists were asked to independently review the breast MRI results, to grade the degree of high peripheral signal, the rim sign, in the DWI, and to confirm the mean apparent diffusion coefficient (ADC(mean)) values. We analyzed the diagnostic accuracy and compared the consensus (when 4 of 5 independent reviewers agreed) results of the rim sign with the ADC(mean) values. Additionally, we evaluated the correlation between the dynamic contrast-enhanced (DCE)-MRI morphologic appearance and DWI rim sign. ResultsAccording to the consensus results, the rim sign in DWI was observed on 59.7% of malignant lesions and 19.4% of benign lesions. The sensitivity, specificity, and area under the curve (AUC) value for the rim sign in DWI were 59.7%, 80.6%, and 0.701, respectively. The sensitivity, specificity, and AUC value for the ADC(mean) value (criteria 1.46 x 10(-3) mm(2)/sec) were 82.3%, 63.9%, and 0.731, respectively. Based on consensus, no correlation was observed between the DCE-MRI and DWI rim signs. ConclusionIn DWI, a high-signal rim is a valuable morphological feature for improving specificity in DWI. J. Magn. Reson. Imaging 2015;41:616-623. (c) 2014 Wiley Periodicals, Inc.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

breast cancer
magnetic resonance imaging
diffusion-weighted image

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view