SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wolffs Petra)
 

Sökning: WFRF:(Wolffs Petra) > Quantification of C...

Quantification of Campylobacter spp. in chicken rinse samples by using flotation prior to real-time PCR

Wolffs, Petra (författare)
Lund University,Lunds universitet,Teknisk mikrobiologi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Applied Microbiology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Norling, B (författare)
Hoorfar, J (författare)
visa fler...
Griffiths, M (författare)
Rådström, Peter (författare)
Lund University,Lunds universitet,Teknisk mikrobiologi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Applied Microbiology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2005
2005
Engelska.
Ingår i: Applied and Environmental Microbiology. - 0099-2240. ; 71:10, s. 5759-5764
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Real-time PCR is fast, sensitive, specific, and can deliver quantitative data; however, two disadvantages are that this technology is sensitive to inhibition by food and that it does not distinguish between DNA originating from viable, viable nonculturable (VNC), and dead cells. For this reason, real-time PCR has been combined with a novel discontinuous buoyant density gradient method, called flotation, in order to allow detection of only viable and VNC cells of thermotolerant campylobacters in chicken rinse samples. Studying the buoyant densities of different Campylobacter spp. showed that densities changed at different time points during growth; however, all varied between 1.065 and 1.109 g/ml. These data were then used to develop a flotation assay. Results showed that after flotation and real-time PCR, cell concentrations as low as 8.6 X 10(2) CFU/ml could be detected without culture enrichment and amounts as low as 2.6 X 10(3) CFU/ml could be quantified. Furthermore, subjecting viable cells and dead cells to flotation showed that viable cells were recovered after flotation treatment but that dead cells and/or their DNA was not detected. Also, when samples containing VNC cells mixed with dead cells were treated with flotation after storage at 4 or 20 degrees C for 21 days, a similar percentage resembling the VNC cell fraction was detected using real-time PCR and 5-cyano-2,3-ditolyl tetrazolium chloride-4',6'-diamidino-2-phenylindole staining (20% +/- 9% and 23% +/- 4%, respectively, at 4 degrees C; 11% +/- 4% and 10% +/- 2%, respectively, at 20 degrees C). This indicated that viable and VNC Campylobacter cells could be positively selected and quantified using the flotation method.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Wolffs, Petra
Norling, B
Hoorfar, J
Griffiths, M
Rådström, Peter
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Industriell biot ...
Artiklar i publikationen
Applied and Envi ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy