Search: L773:1879 0887 OR L773:0167 8140
> (1995-1999) >
Verification of a d...
Verification of a dynamic wedge implementation in a pencil beam based dose planning system
-
- Weber, Lars (author)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Nilsson, Per (author)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Knöös, Tommy (author)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
show more...
-
Ahnesjö, Anders (author)
-
show less...
-
(creator_code:org_t)
- Elsevier BV, 1995
- 1995
- English.
-
In: Radiotherapy and Oncology. - : Elsevier BV. - 1879-0887 .- 0167-8140. ; 37:Suppl. 1, s. 26-26
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- The use of dynamic movements on linear accelerators during irradiation have found a revised interest lately due to the integration of computers to control the linear accelerator. An example of this is the generation of fields that resemble ordinary wedge fields. These fields are produced by moving one of the collimator blocks during irradiation, i. e. dynamic wedges.A pencil beam based system with the possibility of modelling dynamically modulated dose distributions from collimator movement specifications has extensively been investigated. Special interest has been focused on depth doses, profiles and output factors which have been generated by dynamic wedge fields. The data from the treatment planning system has been verified with measurements in water on a Varian 4 MV linear accelerator.The results indicate that calculations accurately predicts the outcome from dynamic wedges without any additional measurements than those used for characterisation of static open beams.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)