Verification of a dynamic wedge implementation in a pencil beam based dose planning system

Weber, Lars (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Nilsson, Per (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Knöös, Tommy (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Ahnesjö, Anders (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 1995
1995
Engelska.
Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 1879-0887 .- 0167-8140. ; 37:Suppl. 1, s. 26-26
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The use of dynamic movements on linear accelerators during irradiation have found a revised interest lately due to the integration of computers to control the linear accelerator. An example of this is the generation of fields that resemble ordinary wedge fields. These fields are produced by moving one of the collimator blocks during irradiation, i. e. dynamic wedges.A pencil beam based system with the possibility of modelling dynamically modulated dose distributions from collimator movement specifications has extensively been investigated. Special interest has been focused on depth doses, profiles and output factors which have been generated by dynamic wedge fields. The data from the treatment planning system has been verified with measurements in water on a Varian 4 MV linear accelerator.The results indicate that calculations accurately predicts the outcome from dynamic wedges without any additional measurements than those used for characterisation of static open beams.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Weber, Lars
Nilsson, Per
Knöös, Tommy
Ahnesjö, Anders
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Radiotherapy and ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy