Feasibility and safety of synchrotron-based X-ray phase contrast imaging as a technique complementary to histopathology analysis

Li, Kan Yan Chloe (author)
University College London
Dejea, Hector (author)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,MAX IV-laboratoriet,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,MAX IV Laboratory,ETH Zürich,Paul Scherrer Institute
De Winne, Koen (author)
Antwerp University Hospital
show more...
Bonnin, Anne (author)
Paul Scherrer Institute
D’Onofrio, Valentino (author)
Hasselt University
Cox, Janneke A. (author)
Hasselt University
Garcia-Canadilla, Patricia (author)
University of Barcelona
Lammens, Martin (author)
Antwerp University Hospital
Cook, Andrew C. (author)
University College London
Bijnens, Bart (author)
Catalan Institution for Research and Advanced Studies,Institutd' Investigacions Biomèdiques August Pi iSunyer (IDIBAPS)
Dendooven, Amélie (author)
Antwerp University Hospital,Hasselt University
show less...
 (creator_code:org_t)
2023
2023
English 13 s.
In: Histochemistry and Cell Biology. - 0948-6143. ; 160:5, s. 377-389
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • X-ray phase contrast imaging (X-PCI) is a powerful technique for high-resolution, three-dimensional imaging of soft tissue samples in a non-destructive manner. In this technical report, we assess the quality of standard histopathological techniques performed on formalin-fixed, paraffin-embedded (FFPE) human tissue samples that have been irradiated with different doses of X-rays in the context of an X-PCI experiment. The data from this study demonstrate that routine histochemical and immunohistochemical staining quality as well as DNA and RNA analyses are not affected by previous X-PCI on human FFPE samples. From these data we conclude it is feasible and acceptable to perform X-PCI on FFPE human biopsies.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Keyword

Needle biopsies
Pathology
X-ray phase contrast imaging

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view