SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Brun R)
 

Sökning: WFRF:(Brun R) > (1995-1999) > Blood-brain barrier...

Blood-brain barrier permeability in rats exposed to electromagnetic fields used in wireless communication

Persson, Bertil R (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Salford, Leif G. (författare)
Brun, Arne (författare)
Lund University,Lunds universitet,Neurokirurgi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Tumörmikromiljö,Sektion I,Institutionen för kliniska vetenskaper, Lund,Neurosurgery,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine,Tumor microenvironment,Section I,Department of Clinical Sciences, Lund
 (creator_code:org_t)
1997
1997
Engelska.
Ingår i: Wireless Networks. - 1022-0038. ; 3, s. 455-461
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • iological effects of radio frequency electromagnetic fields (EMF) on the blood-brain barrier (BBB) have been studied in Fischer 344 rats of both sexes. The rats were not anaesthetised during the exposure. All animals were sacrificed by perfusion–fixation of the brains under chloralhydrate anaesthesia after the exposure. The brains were perfused with saline for 3–4 minutes, and thereafter perfusion fixed with 4% formaldehyde for 5–6 minutes. Whole coronal sections of the brains were dehydrated and embedded in paraffin and sectioned at 5 m. Albumin and fibrinogen were demonstrated immunohistochemically and classified as normal versus pathological leakage. In the present investigation we exposed male and female Fischer 344 rats in a Transverse Electromagnetic Transmission line chamber to microwaves of 915 MHz as continuous wave (CW) and pulse-modulated with different pulse power and at various time intervals. The CW-pulse power varied from 0.001 W to 10 W and the exposure time from 2 min to 960 min. In each experiment we exposed 4–6 rats with 2–4 controls randomly placed in excited and non-excited TEM-cells respectively. We have in total investigated 630 exposed rats at various modulation frequencies and 372 controls. The frequency of pathological rats is significantly increased (p < 0:0001) from 62=372 (ratio: 0:170:02) for control rats to 244=630 (ratio: 0:390:03) in all exposed rats. Grouping the exposed animals according to the level of specific absorbed energy (J/kg) give significant difference in all levels above 1.5 J/kg. The exposure was 915 MHz microwaves either pulse modulated (PW) at 217 Hz with 0.57 ms pulse width, at 50 Hz with 6.6 ms pulse width or continuous wave (CW). The frequency of pathological rats (0:17) among controls in the various groups is not significantly different. The frequency of pathological rats was 170=481 (0:350:03) among rats exposed to pulse modulated (PW) and 74=149 (0:500:07) among rats exposed to continuous wave exposure (CW). These results are both highly significantly different to their corresponding controls (p < 0:0001) and the frequency of pathological rats after exposure to pulsed radiation (PW) is significantly less (p < 0:002) than after exposure to continuous radiation (CW).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Annan klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Other Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Blood-brain barrier
permeability
rats
electromagnetic
fields
wireless
communication

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Persson, Bertil ...
Salford, Leif G.
Brun, Arne
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Annan klinisk me ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Wireless Network ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy