SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Östling Gerd)
 

Sökning: WFRF:(Östling Gerd) > Comparison of grey ...

Comparison of grey scale median (GSM) measurement in ultrasound images of human carotid plaques using two different softwares.

Östling, Gerd (författare)
Lund University,Lunds universitet,Kardiovaskulär forskning - immunitet och ateroskleros,Forskargrupper vid Lunds universitet,Internmedicin - epidemiologi,Cardiovascular Research - Immunity and Atherosclerosis,Lund University Research Groups,Internal Medicine - Epidemiology
Persson, Margaretha (författare)
Lund University,Lunds universitet,Internmedicin - epidemiologi,Forskargrupper vid Lunds universitet,Internal Medicine - Epidemiology,Lund University Research Groups
Hedblad, Bo (författare)
Lund University,Lunds universitet,Kardiovaskulär forskning - epidemiologi,Forskargrupper vid Lunds universitet,Cardiovascular Research - Epidemiology,Lund University Research Groups
visa fler...
Goncalves, Isabel (författare)
Lund University,Lunds universitet,Kardiovaskulär forskning - immunitet och ateroskleros,Forskargrupper vid Lunds universitet,Kardiovaskulär forskning - translationella studier,Cardiovascular Research - Immunity and Atherosclerosis,Lund University Research Groups,Cardiovascular Research - Translational Studies
visa färre...
 (creator_code:org_t)
2013-05-13
2013
Engelska.
Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961. ; 33:6, s. 431-435
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Grey scale median (GSM) measured on ultrasound images of carotid plaques has been used for several years now in research to find the vulnerable plaque. Centres have used different software and also different methods for GSM measurement. This has resulted in a wide range of GSM values and cut-off values for the detection of the vulnerable plaque. The aim of this study was to compare the values obtained with two different softwares, using different standardization methods, for the measurement of GSM on ultrasound images of carotid human plaques. GSM was measured with Adobe Photoshop(®) and with Artery Measurement System (AMS) on duplex ultrasound images of 100 consecutive medium- to large-sized carotid plaques of the Beta-blocker Cholesterol-lowering Asymptomatic Plaque Study (BCAPS). The mean values of GSM were 35·2 ± 19·3 and 55·8 ± 22·5 for Adobe Photoshop(®) and AMS, respectively. Mean difference was 20·45 (95% CI: 19·17-21·73). Although the absolute values of GSM differed, the agreement between the two measurements was good, correlation coefficient 0·95. A chi-square test revealed a kappa value of 0·68 when studying quartiles of GSM. The intra-observer variability was 1·9% for AMS and 2·5% for Adobe Photoshop. The difference between softwares and standardization methods must be taken into consideration when comparing studies. To avoid these problems, researcher should come to a consensus regarding software and standardization method for GSM measurement on ultrasound images of plaque in the arteries.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Östling, Gerd
Persson, Margare ...
Hedblad, Bo
Goncalves, Isabe ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy