A flow immunoassay for alkylphenol ethoxylate surfactants and their metabolites - questions associated with cross-reactivity, matrix effects, and validation by chromatographic techniques

Badea, M (författare)
Nistor, Catalin (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Goda, Y (författare)
visa fler...
Fujimoto, S (författare)
Dosho, S (författare)
Danet, A (författare)
Barcelo, D (författare)
Ventura, F (författare)
Emnéus, Jenny (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2003
2003
Engelska.
Ingår i: Analyst. - : Royal Society of Chemistry (RSC). - 1364-5528. ; 128:7, s. 849-856
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper describes the application and evaluation of a competitive enzyme flow injection immunoassay (EFIIA) for screening of alkylphenol ethoxylate (APEO) surfactants in different water samples based on a generic immunoassay system previously developed ( see E. Burestedt, C Nistor, U. Schagerlof and J. Emneus, Anal. Chem., 2000, 72, 4171 - 4177). The detection limits for octylphenol ethoxylates (OPEOs), nonylphenol ethoxylates (NPEOs), and nonylphenol (NP) were 0.5 mug l(-1), between 2 and 3 mug l(-1), and 50 mug l(-1), respectively, with a sample throughput of 6 h(-1) (i.e., for triplicate analysis of each sample). Different OPEOs and NPEOs were highly cross-reactive within the assay, with sensitivities in the same order of magnitude for all the ethoxylates tested, thus the result obtained by the EFIIA method could be used as an "alkylphenol ethoxylate index". No or minor matrix effects with recoveries between 70 - 120% for the reference analyte NPEO10 in tap, and surface water, and acceptable for rainwater, were observed. Influent and effluent surfactant containing wastewater samples were analysed by EFIIA, LC-MS, LC-Fluoresence (LC-FL), and a commercial microplate ELISA. High recoveries for different concentrations of APEO(10) spiked into a 200 times diluted raw influent and effluent wastewater were achieved with the EFIIA method, however, the found APEO content of the same diluted wastewater samples, before spiking, could not be correlated directly to the chromatographic result by any of the immunoassays, and the possible reasons for this are discussed. The same trend of decreasing APEO content from influent to effluent wastewater could, however, be followed for all methods employed.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Analyst (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy