SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ivert Torbjörn)
 

Sökning: WFRF:(Ivert Torbjörn) > Active chest tube c...

Active chest tube clearance after aortic valve surgery did not influence amount residual pericardial fluid after aortic valve replacement in a randomised trial

Malgerud, Linnéa (författare)
Karolinska Institute,Karolinska University Hospital
Maret, Eva (författare)
Karolinska Institutet,Karolinska Institute,Karolinska University Hospital
Reitan, Christian (författare)
Karolinska Institutet,Lund University,Lunds universitet,Arrhytmias and Cardiac Device treatment,Forskargrupper vid Lunds universitet,Lund University Research Groups,Karolinska University Hospital
visa fler...
Ivert, Torbjörn (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2020-03-03
2020
Engelska 6 s.
Ingår i: Scandinavian Cardiovascular Journal. - : Informa UK Limited. - 1401-7431 .- 1651-2006. ; 54:3, s. 200-205
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective. Evaluate if the use of active clearance of chest tubes after aortic valve surgery influenced bleeding and reduced postoperative residual pericardial effusion. Design. Prospective randomised trial comparing PleuraFlow® 32 F chest tube with FlowGlide™ active clearance to a standard Argyle® 32 F chest tube in 100 patients undergoing aortic valve surgery. Chest tube outputs and pericardial effusion measurements assessed by two-dimensional transthoracic echocardiography were recorded before hospital discharge. Results. Postoperative chest tube outputs per hour did not differ between the two groups. The median chest tube output was 400 mL for patients who had a PleuraFlow® chest tube vs. 490 mL for patients with an Argyle® chest tube (p =.08). Pericardial effusions ≥ 2 mm were detected in 76% vs. 68% of the patients (p =.50) and postoperative atrial fibrillation occurred in 42% vs. 34% (p =.54), respectively. Conclusions. Use of active clearance chest tubes, compared to standard chest tubes after aortic valve surgery did not differ significantly regarding postoperative bleeding or degree of pericardial effusion as measured by echocardiography prior to hospital discharge.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

active clearance
Aortic valve replacement
chest tubes
echocardiography
pericardial effusion

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Malgerud, Linnéa
Maret, Eva
Reitan, Christia ...
Ivert, Torbjörn
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Scandinavian Car ...
Av lärosätet
Lunds universitet
Karolinska Institutet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy