A PHANTOM STUDY SHOWING THE IMPORTANCE OF COMPRESSION IN CONVENTIONAL DIAGNOSTIC X-RAY EXAMINATIONS.

Aurumskjöld, Marie-Louise (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Tingberg, Anders (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Mattsson, Sören (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
 (creator_code:org_t)
2010-03-05
2010
Engelska.
Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; Apr 7, s. 78-80
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Compression was earlier an important and well-managed part of the clinical routine, but during the past 15-20 y the use has diminished, except for mammography, where it is a prerequisite for having images of high quality and low radiation dose. According to national and European regulations and recommendations, it is important to apply the compression technique to obtain the optimal image quality and radiation dose in common conventional diagnostic examinations. Current experience of compression technique is, however, based on studies carried out a long time ago and with analogue imaging techniques. An anthropomorphic phantom was used to show the importance of compression in conventional X-ray examinations. The patient thicknesses on volunteers with and without compression was measured. This measurement was done to investigate compression potential on patients and to select suitable phantom thicknesses. The X-ray examinations that were included in the study were abdomen overview, lumbar spine and the pelvis. The results from the phantom study showed a large dependency of the kerma-area product value on the phantom thickness. The phantom study suggests that there is a potential for significant reduction of radiation dose to the patient by using compression also with modern X-ray techniques. A dose reduction of up to 50 % or even more may be obtained.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Aurumskjöld, Mar ...
Tingberg, Anders
Mattsson, Sören
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Radiation Protec ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy