Sökning: WFRF:(Rogmark Peder) >
Suture-TOOL : A sut...
Suture-TOOL : A suturing device for swift and standardized abdominal aponeurosis closure
-
- Börner, Gabriel (författare)
- Helsingborg Hospital
-
- Edelhamre, Marcus (författare)
- Helsingborg Hospital
-
- Rogmark, Peder (författare)
- Lund University,Lunds universitet,Kirurgi,Forskargrupper vid Lunds universitet,Surgery,Lund University Research Groups,Skåne University Hospital
-
visa fler...
-
- Montgomery, Agneta (författare)
- Lund University,Lunds universitet,Kirurgi,Forskargrupper vid Lunds universitet,Surgery,Lund University Research Groups,Skåne University Hospital
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2022
- 2022
- Engelska.
-
Ingår i: Surgery in Practice and Science. - : Elsevier BV. - 2666-2620. ; 11
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Introduction: Surgeons can reduce incisional hernia formation by adhering to standardized techniques for incisional wound closure. This is often neglected by the time a long operation is to be ended and can lead to the risk of developing an incisional hernia or a wound rupture. To address this issue, a suturing machine (Suture-TOOL) was developed for swift and standardized abdominal closure. The aim was to compare the user safety, speed, and suturing quality between Suture-TOOL and manual Needle-Driver suturing. Method: Fifteen surgeons who were specialists in surgery, urology, and gynaecology as well as surgical trainees were invited. The Suture-TOOL was presented to the surgeons who read the instructions for use before starting the test. Each surgeon closed nine 15 cm-long incisions in a human body model; six with Suture-TOOL and three with the Needle-Driver technique. Gloves were examined for puncture damage. Endpoints were suture-length/wound-length (SL/WL)-ratio, closure time, number of stitches, learning curve, and glove puncture rate. A VAS-evaluation concerning different Suture-Tool user impressions was completed. Results: A SL/WL-ratio ≥4 was 98% for Suture-TOOL versus 69% for Needle-Driver (p < 0.001). Suture time was shorter for Suture-TOOL (p < 0.001). Wound stitch count was higher for Needle-Driver (p = 0.013). The median SL/WL-ratio was similar between groups. The learning curve plateaued after three closures using Suture-TOOL. Two glove punctures were detected—all in the Needle-Driver group. Suture-TOOL received high VAS scores for all measured functionalities. Conclusion: Suture-TOOL is a promising device for clinical use. It is safe, easy, and fast resulting in a high-quality suture lines with a short learning curve and a high functionality ranking.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kirurgi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Surgery (hsv//eng)
Nyckelord
- Abdominal wall closure
- Mechanical device
- Standardization
- Suture device
- Suture technique
- Wound closure technique
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas