SwePub
Sök i LIBRIS databas

  Utökad sökning

(AMNE:(MEDICIN OCH HÄLSOVETENSKAP Klinisk medicin Kardiologi))
 

Sökning: (AMNE:(MEDICIN OCH HÄLSOVETENSKAP Klinisk medicin Kardiologi)) > (1995-1999) > Endovascular stent-...

Endovascular stent-anchored aortic grafts: a comparison between self-expanding and balloon-expandable stents in minipigs

Lindh, Mats (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Malina, Martin (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Department of Clinical Sciences, Malmö,Faculty of Medicine,Vascular Diseases - Clinical Research,Lund University Research Groups
Ivancev, K (författare)
visa fler...
Brunkwall, J (författare)
Lindblad, Bengt (författare)
Lund University,Lunds universitet,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Vascular Diseases - Clinical Research,Lund University Research Groups
visa färre...
 (creator_code:org_t)
1996
1996
Engelska.
Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 3:3, s. 284-289
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To study endovascular graft attachment with self-expanding Gianturco Z-stents and balloon-expanded Palmaz stents and the effect of these devices on the renal ostia. METHODS: Ten stent-grafts were constructed, 5 with Gianturco Z-stents and 5 with Palmaz stents. The endografts were implanted under fluoroscopic guidance into the abdominal aorta of 10 pigs so that the uncovered portion of the proximal stent extended over the renal artery orifices. Distal aortic blood pressure and flow were measured before and after graft placement and 1 hour postprocedure. The aorta was then exposed surgically, and the central portion of the stent-graft was inspected through an aortotomy to assess perigraft leakage. RESULTS: Stent-graft implantation was accurate and hemostatic in all cases, despite longitudinal folding of the graft due to oversizing. However, transverse folds produced pressure gradients (> 15 mmHg) between the ends of the graft in two cases. In another case, a pressure gradient resulted from partial thrombosis of the graft. In two cases, renal artery occlusion and thrombosis occurred due to coverage by the graft material. In two other animals, one of the renal arteries was entirely uncovered by a stent. The remaining 16 renal arteries were covered by the proximal stent but not the graft, as intended. One (6.25%) of these arteries thrombosed, but the remainder were grossly patent when the animals were sacrificed at 1 hour. CONCLUSIONS: Both Palmaz and Gianturco Z-stents produced hemostatic endovascular graft attachment, even in the presence of moderate graft oversizing. The risk of acute renal artery occlusion from juxtarenal stenting does not appear to be prohibitive, but longer term observations are needed.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

endoprostheses
stent-graft
stents
endoluminal graft
experimental study

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lindh, Mats
Malina, Martin
Ivancev, K
Brunkwall, J
Lindblad, Bengt
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Journal of Endov ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy