SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Jönsson Bo)
 

Sökning: WFRF:(Jönsson Bo) > (1990-1994) > Method for analysis...

Method for analysis of methyltetrahydrophthalic acid in urine using gas chromatography and selected ion monitoring

Lindh, Christian (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine
Jönsson, Bo A (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine
 (creator_code:org_t)
Elsevier BV, 1994
1994
Engelska.
Ingår i: Journal of chromatography. B, Biomedical applications. - : Elsevier BV. - 1572-6495 .- 0378-4347. ; 660:1, s. 57-66
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A method for the determination of methyltetrahydrophthalic acid (MTHP acid), a metabolite of methyltetrahydrophthalic anhydride (MTHPA) in human urine, was developed. The investigated MTHP acid was obtained by hydrolysis of a commercial MTHPA mixture, composed of three major isomers. These were synthesized and identified as 3-methyl-delta 4-tetrahydrophthalic anhydride, 4-methyl-delta 4-tetrahydrophthalic anhydride and 4-methyl-delta 3-tetrahydrophthalic anhydride. The urine was worked up by a liquid-solid extraction technique using C18 sorbent columns. Esterification was performed with methanol and boron trifluoride. The derivative in toluene was analyzed with capillary gas chromatography and selected ion monitoring. Deuterium-labeled MTHP acid was used as internal standard. The intra-assay precision for the overall method was between 4 and 8% in the range 3-110 ng/ml and the inter-assay precision was between 4 and 7% in the range 30-110 ng/ml. The total recoveries of the MTHP acid at 19 and 190 ng/ml were 94 and 97%, respectively. The total detection limit for the three isomers was < 6 ng/ml. Analysis of urine from a worker exposed to MTHPA makes it reasonable to assume that the method may be used for biological monitoring of MTHPA exposure.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lindh, Christian
Jönsson, Bo A
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Arbetsmedicin oc ...
Artiklar i publikationen
Journal of chrom ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy