SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Kern P)
 

Sökning: WFRF:(Kern P) > The superconducting...

The superconducting radio-frequency linear accelerator components for the European spallation source : First test results

Darve, C. (författare)
Lund University,Lunds universitet,European Spallation Source ESS AB,Stiftelser och övriga anknutna verksamheter,Other Institutions and Utilities
Elias, N. (författare)
Schlander, F. (författare)
visa fler...
Bosland, P. (författare)
Arcambal, C. (författare)
Cenni, E. (författare)
Devanz, G. (författare)
Peauger, F. (författare)
Olry, G. (författare)
Institut de Physique Nucléaire Orsay (IPN) Orsay
Bousson, S. (författare)
Institut de Physique Nucléaire Orsay (IPN) Orsay
Duthil, P. (författare)
Institut de Physique Nucléaire Orsay (IPN) Orsay
Olivier, G. (författare)
Institut de Physique Nucléaire Orsay (IPN) Orsay
Reynet, D. (författare)
Institut de Physique Nucléaire Orsay (IPN) Orsay
Costanza, G. (författare)
Lund University,Lunds universitet,Teoretisk elektroteknik,Forskargrupper vid Lunds universitet,Electromagnetic Theory,Lund University Research Groups
Ruber, R. (författare)
Uppsala University
Li, H. (författare)
Uppsala University
Santiago Kern, R. (författare)
Uppsala University
visa färre...
 (creator_code:org_t)
2016
2016
Engelska 6 s.
Ingår i: Proceedings of the 28th Linear Accelerator Conference, LINAC 2016. - 9783954501694 ; , s. 651-656
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The European Spallation Source requires a pulsed linac with an average beam power on the target of 5 MW, which is about five times higher than the most powerful spallation source in operation today. Over 97 % of the acceleration occurs in superconducting cavities. ESS will be the first accelerator to employ double spoke cavities to accelerate beam. Accelerating gradients of 9 MV/meter is required in the spoke section. The spoke section will be followed by 36 elliptical 704 MHz cavities with a geometrical E of 0.67 and elliptical 704 MHz cavities with a geometrical E of 0.86. Accelerating gradients of 16.7 and 20 MV/m are required in the medium and high-E elliptical cavities, respectively. Initial gradient test results will be presented in which results exceed expected requirements.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy