SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:lup.lub.lu.se:95ee23c0-84a8-4647-9fa0-f1a15d0fb6c0"
 

Search: id:"swepub:oai:lup.lub.lu.se:95ee23c0-84a8-4647-9fa0-f1a15d0fb6c0" > On the automation o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Abou Nada, Fahd JoudaLund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH (author)

On the automation of thermographic phosphor calibration

  • Article/chapterEnglish2014

Publisher, publication year, extent ...

  • 2014
  • 6 s.
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:lup.lub.lu.se:95ee23c0-84a8-4647-9fa0-f1a15d0fb6c0
  • https://lup.lub.lu.se/record/4530120URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:kon swepub-publicationtype
  • Subject category:ref swepub-contenttype

Notes

  • Thermographic phosphors can be robust temperature remote sensors. The accuracy of the temperature measured by the phosphor is highly dependent on the quality of the phosphor calibration used. Conventionally, thermographic phosphors are calibrated by measuring a series of decay curves at known stable oven temperatures. The process is then repeated covering the thermal sensitivity range of the phosphor chosen. Heating and cooling rates of high temperature ovens are usually low. Also, thermal equilibrium of the system is required at each calibration temperature before acquiring luminescence decay curves. Thus, the process is usually time consuming and the number of calibration points achieved is limited to a couple of dozen points. This study presents and validates the development of an automatic routine for the calibration of thermographic phosphors. It was designed to continuously and simultaneously acquire phosphor decay curves along with their corresponding thermocouple temperatures. The developed routine required software and hardware improvements. An updated design of the calibration substrate was implemented to improve the thermal conditions during calibration. Thermal gradients were further studied using a heat transfer model. The routine implemented a specially designed sparsing algorithm that reduced the sampling rate of the decaying luminescence curve without influencing the calculated decay time. The upper heating rate is set at 4 K.min-1 due to limitation imposed by the ceramic calibration oven. The phosphors CdWO4 and Mg3F2GeO4:Mn were chosen to validate the finalized routine. After the completion of the calibration process, a library-based calibration is created as the final product. The automated calibration routine delivered an overall accuracy improvement of 1-2 K, reduced calibration duration by factor of four and provided the possibility of deriving signal recognition algorithms. The condensed calibration dataset produced by the proposed calibration routine was further employed to develop a novel signal shape recognition algorithm for temperature evaluation.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Knappe, ChristophLund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)forb-csk (author)
  • Xu, Xin (author)
  • Richter, MattiasLund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)forb-mri (author)
  • Aldén, MarcusLund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)forb-mal (author)
  • FörbränningsfysikFysiska institutionen (creator_code:org_t)

Related titles

  • In:Proceedings of the 60th International Instrumentation Symposium

Internet link

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Abou Nada, Fahd ...
Knappe, Christop ...
Xu, Xin
Richter, Mattias
Aldén, Marcus
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Physical Science ...
and Atom and Molecul ...
Articles in the publication
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view