SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Antonsson Stefan)
 

Sökning: WFRF:(Antonsson Stefan) > Measurements of opt...

Measurements of optical properties of pig brain tissue in vitro using a novel compact device

Yavari, Nazila (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Dam, Jan Sorensen (författare)
Antonsson, Johan (författare)
visa fler...
Wardell, Karin (författare)
Andersson-Engels, Stefan (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
SPIE, 2005
2005
Engelska.
Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422 .- 1042-4687. ; 5864, s. 1-11
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • In numerous medical and scientific fields, knowledge of the optical properties of tissues can be applied. Among many different ways of determining the optical properties of turbid media; integrating sphere measurements are widely used. However, this technique is associated with bulky equipment, complicated measuring techniques, interference compensation techniques, and inconvenient sample handling. This paper describes measurements of the optical properties of porcine brain tissue using novel instrumentation for simultaneous absorption and scattering characterization of small turbid samples. The system used measures both angularly and spatially resolved transmission and reflection and is called Combined Angular and Spatially-resolved Head (CASH) sensor. The results compare very well with data obtained with an integrating sphere for well-defined samples. The instrument was shown to be accurate to within 12 % for μa. and 1 % for μs' in measurements of intralipid-ink samples. The corresponding variations of data were 17 %, and 2 %, respectively. The reduced scattering coefficient for porcine white matter was measured to be 100 cm-1, while the value for coagulated brain tissue was 65 cm-1. The corresponding absorption coefficients were 2 and 3 cm-1, respectively. © 2005 SPIE and OSA.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

Absorption coefficients
Pig brain tissue
Turbid media
Optical device

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy