SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Antonsson Stefan)
 

Sökning: WFRF:(Antonsson Stefan) > Measurements of opt...

  • Yavari, NazilaLund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH (författare)

Measurements of optical properties of pig brain tissue in vitro using a novel compact device

  • Artikel/kapitelEngelska2005

Förlag, utgivningsår, omfång ...

  • SPIE,2005

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:989b4f8d-cc65-41d0-8584-06afa5a8627d
  • https://lup.lub.lu.se/record/615937URI
  • https://doi.org/10.1117/12.632926DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:kon swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • In numerous medical and scientific fields, knowledge of the optical properties of tissues can be applied. Among many different ways of determining the optical properties of turbid media; integrating sphere measurements are widely used. However, this technique is associated with bulky equipment, complicated measuring techniques, interference compensation techniques, and inconvenient sample handling. This paper describes measurements of the optical properties of porcine brain tissue using novel instrumentation for simultaneous absorption and scattering characterization of small turbid samples. The system used measures both angularly and spatially resolved transmission and reflection and is called Combined Angular and Spatially-resolved Head (CASH) sensor. The results compare very well with data obtained with an integrating sphere for well-defined samples. The instrument was shown to be accurate to within 12 % for μa. and 1 % for μs' in measurements of intralipid-ink samples. The corresponding variations of data were 17 %, and 2 %, respectively. The reduced scattering coefficient for porcine white matter was measured to be 100 cm-1, while the value for coagulated brain tissue was 65 cm-1. The corresponding absorption coefficients were 2 and 3 cm-1, respectively. © 2005 SPIE and OSA.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Dam, Jan Sorensen (författare)
  • Antonsson, Johan (författare)
  • Wardell, Karin (författare)
  • Andersson-Engels, StefanLund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)fysi-san (författare)
  • AtomfysikFysiska institutionen (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Progress in Biomedical Optics and Imaging - Proceedings of SPIE: SPIE5864, s. 1-111605-74221042-4687

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy