SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Christensson Magnus)
 

Sökning: WFRF:(Christensson Magnus) > (2010-2014) > Linalool - a signif...

Linalool - a significant contact sensitizer after air exposure

Bråred Christensson, Johanna, 1965 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för dermatologi och venereologi,Institute of Clinical Sciences, Department of Dermatology and Venereology
Matura, Mihaly, 1964 (författare)
Karolinska Institutet,Gothenburg University,Göteborgs universitet,Institutionen för kemi,Department of Chemistry
Gruvberger, Birgitta (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
visa fler...
Bruze, Magnus (författare)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
Karlberg, Ann-Therese, 1947 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi,Department of Chemistry
visa färre...
 (creator_code:org_t)
Wiley, 2010
2010
Engelska.
Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 62:1, s. 32-41
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Linalool is a widely used fragrance terpene. Pure linalool is not allergenic or a very weak allergen, but autoxidizes on air exposure and the oxidation products can cause contact allergy. Oxidized (ox.) linalool has previously been patch tested at a concentration of 2.0% in petrolatum (pet.) in 1511 patients, and 1.3% positive patch test reactions were observed. Objective: To investigate the optimal patch test concentration for detection of contact allergy to ox. linalool. Methods: Four concentrations of ox. linalool (2.0%, 4.0%, 6.0%, 11.0% pet.) were tested in 3418 consecutive dermatitis patients. Results: Ox. linalool 2.0%, 4.0%, 6.0%, and 11.0% pet. detected positive patch test reactions in 0.83%, 3.2%, 5.3%, and 7.2% of the tested patients, respectively. The doubtful reactions increased with rising concentrations but relatively less, giving 5.1%, 6.4%, and 7.3% doubtful reactions, respectively, for ox. linalool 4.0%, 6.0%, and 11.0% pet. Few irritative reactions were seen. Conclusions: Raising the patch test concentration for ox. linalool gave a better detection of contact allergy, as many as 5-7% positive patch test reactions were detected. We suggest a patch test concentration of ox. linalool 6.0% pet. for future patch testing, giving a dose per unit area of 2.4 mg/cm(2) when 20 mg test substance is tested in small Finn Chambers (R).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Dermatologi och venereologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dermatology and Venereal Diseases (hsv//eng)
NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

patch
test concentration
patch testing
terpenes
oxidation products
linalool
hydroperoxides
fragrance allergy
dose per unit area
allergic contact dermatitis
autoxidation
allergic contact dermatitis • autoxidation • dose per unit area • fragrance allergy • hydroperoxides • linalool • oxidation products • patch test concentration • patch testing • terpenes

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy