SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:9b5d59c5-463f-46d2-b4df-4e61611bcf6c"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:9b5d59c5-463f-46d2-b4df-4e61611bcf6c" > The frequency of at...

The frequency of atrial fibrillatory waves is modulated by the spatiotemporal pattern of acetylcholine release : a 3D computational study

Celotto, Chiara (författare)
University of Zaragoza
Sánchez, Carlos (författare)
University of Zaragoza
Abdollahpur, Mostafa (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Sandberg, Frida (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Rodriguez, Jose F. (författare)
Polytechnic University of Milan
Laguna, Pablo (författare)
University of Zaragoza
Pueyo, Esther (författare)
University of Zaragoza
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: Frontiers in Physiology. - 1664-042X. ; 14
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In atrial fibrillation (AF), the ECG P-wave, which represents atrial depolarization, is replaced with chaotic and irregular fibrillation waves (f waves). The f-wave frequency, F f, shows significant variations over time. Cardiorespiratory interactions regulated by the autonomic nervous system have been suggested to play a role in such variations. We conducted a simulation study to test whether the spatiotemporal release pattern of the parasympathetic neurotransmitter acetylcholine (ACh) modulates the frequency of atrial reentrant circuits. Understanding parasympathetic involvement in AF may guide more effective treatment approaches and could help to design autonomic markers alternative to heart rate variability (HRV), which is not available in AF patients. 2D tissue and 3D whole-atria models of human atrial electrophysiology in persistent AF were built. Different ACh release percentages (8% and 30%) and spatial ACh release patterns, including spatially random release and release from ganglionated plexi (GPs) and associated nerves, were considered. The temporal pattern of ACh release, ACh( t), was simulated following a sinusoidal waveform of frequency 0.125 Hz to represent the respiratory frequency. Different mean concentrations ( A C h ¯ ) and peak-to-peak ranges of ACh (ΔACh) were tested. We found that temporal variations in F f, F f( t), followed the simulated temporal ACh( t) pattern in all cases. The temporal mean of F f( t), F ¯ f , depended on the fibrillatory pattern (number and location of rotors), the percentage of ACh release nodes and A C h ¯ . The magnitude of F f( t) modulation, Δ F f, depended on the percentage of ACh release nodes and ΔACh. The spatial pattern of ACh release did not have an impact on F ¯ f and only a mild impact on Δ F f. The f-wave frequency, being indicative of vagal activity, has the potential to drive autonomic-based therapeutic actions and could replace HRV markers not quantifiable from AF patients.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)