SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Fabian Alexander)
 

Search: WFRF:(Fabian Alexander) > (2010-2014) > Pulmonary Emphysema...

Pulmonary Emphysema Diagnosis with a Preclinical Small-Animal X-ray Dark-Field Scatter-Contrast Scanner

Yaroshenko, Andre (author)
Meinel, Felix G. (author)
Bech, Martin (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
show more...
Tapfer, Arne (author)
Velroyen, Astrid (author)
Schleede, Simone (author)
Auweter, Sigrid (author)
Bohla, Alexander (author)
Yildirim, Ali Oe. (author)
Nikolaou, Konstantin (author)
Bamberg, Fabian (author)
Eickelberg, Oliver (author)
Reiser, Maximilian F. (author)
Pfeiffer, Franz (author)
show less...
 (creator_code:org_t)
Radiological Society of North America (RSNA), 2013
2013
English.
In: Radiology. - : Radiological Society of North America (RSNA). - 1527-1315 .- 0033-8419. ; 269:2, s. 426-432
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Purpose: To test the hypothesis that the joint distribution of x-ray transmission and dark-field signals obtained with a compact cone-beam preclinical scanner with a polychromatic source can be used to diagnose pulmonary emphysema in ex vivo murine lungs. Materials and Methods: The animal care committee approved this study. Three excised murine lungs with pulmonary emphysema and three excised murine control lungs were imaged ex vivo by using a grating-based micro-computed tomographic (CT) scanner. To evaluate the diagnostic value, the natural logarithm of relative transmission and the natural logarithm of dark-field scatter signal were plotted on a per-pixel basis on a scatterplot. Probability density function was fit to the joint distribution by using principle component analysis. An emphysema map was calculated based on the fitted probability density function. Results: The two-dimensional scatterplot showed a characteristic difference between control and emphysematous lungs. Control lungs had lower average median logarithmic transmission (-0.29 vs -0.18, P = .1) and lower average dark-field signal (-0.54 vs -0.37, P = .1) than emphysematous lungs. The angle to the vertical axis of the fitted regions also varied significantly (7.8 degrees for control lungs vs 15.9 degrees for emphysematous lungs). The calculated emphysema distribution map showed good agreement with histologic findings. Conclusion: X-ray dark-field scatter images of murine lungs obtained with a preclinical scanner can be used in the diagnosis of pulmonary emphysema. (C) RSNA, 2013

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

  • Radiology (Search for host publication in LIBRIS)

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view