SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Petersson F)) srt2:(2000-2004)
 

Sökning: (WFRF:(Petersson F)) srt2:(2000-2004) > Gradient echo imagi...

Gradient echo imaging of flowing hyperpolarized nuclei : theory and phantom studies on 129Xe dissolved in ethanol

Johansson, Edvin (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Svensson, Jonas (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Månsson, S (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa fler...
Petersson, J S (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Olsson, L E (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Golman, K (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Ståhlberg, F (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medicinsk strålningsfysik, Lund,Institutionen för kliniska vetenskaper, Lund,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Medical Radiation Physics, Lund,Department of Clinical Sciences, Lund
visa färre...
 (creator_code:org_t)
2002
2002
Engelska 8 s.
Ingår i: Journal of Magnetic Resonance. - 1090-7807 .- 1096-0856. ; 159:1, s. 68-75
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The influence of flip angle and flow velocity on the signal intensity achieved when imaging a hyperpolarized substance with a spoiled gradient echo sequence was investigated. The study was performed both theoretically and experimentally using hyperpolarized xenon dissolved in ethanol. Analytical expressions regarding the optimal flip angle with respect to signal and the corresponding signal level are presented and comparisons with thermally polarized substances are made. Both experimentally and theoretically, the optimal flip angle was found to increase with increasing flow velocity. Numerical calculations showed that the velocity dependence of the signal differs between the cases of hyperpolarized and thermally polarized substances.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Echo-Planar Imaging
Ethanol
Magnetic Resonance Angiography
Phantoms, Imaging
Xenon Isotopes

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy