SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Radwan Jacek)
 

Sökning: WFRF:(Radwan Jacek) > Testing genotyping ...

Testing genotyping strategies for ultra-deep sequencing of a co-amplifying gene family : MHC class I in a passerine bird

Biedrzycka, Aleksandra (författare)
Institute of Nature Conservation of the Polish Academy of Sciences
Sebastian, Alvaro (författare)
Adam Mickiewicz University in Poznań
Migalska, Magdalena (författare)
Adam Mickiewicz University in Poznań
visa fler...
Westerdahl, Helena (författare)
Lund University,Lunds universitet,MEMEG,Biologiska institutionen,Naturvetenskapliga fakulteten,Molekylär ekologi och evolution,Forskargrupper vid Lunds universitet,Department of Biology,Faculty of Science,Molecular Ecology and Evolution Lab,Lund University Research Groups
Radwan, Jacek (författare)
Adam Mickiewicz University in Poznań
visa färre...
 (creator_code:org_t)
2016-11-18
2017
Engelska.
Ingår i: Molecular Ecology Resources. - : Wiley. - 1755-098X. ; 17:4, s. 642-655
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Characterization of highly duplicated genes, such as genes of the major histocompatibility complex (MHC), where multiple loci often co-amplify, has until recently been hindered by insufficient read depths per amplicon. Here, we used ultra-deep Illumina sequencing to resolve genotypes at exon 3 of MHC class I genes in the sedge warbler (Acrocephalus schoenobaenus). We sequenced 24 individuals in two replicates and used this data, as well as a simulated data set, to test the effect of amplicon coverage (range: 500-20 000 reads per amplicon) on the repeatability of genotyping using four different genotyping approaches. A third replicate employed unique barcoding to assess the extent of tag jumping, that is swapping of individual tag identifiers, which may confound genotyping. The reliability of MHC genotyping increased with coverage and approached or exceeded 90% within-method repeatability of allele calling at coverages of >5000 reads per amplicon. We found generally high agreement between genotyping methods, especially at high coverages. High reliability of the tested genotyping approaches was further supported by our analysis of the simulated data set, although the genotyping approach relying primarily on replication of variants in independent amplicons proved sensitive to repeatable errors. According to the most repeatable genotyping method, the number of co-amplifying variants per individual ranged from 19 to 42. Tag jumping was detectable, but at such low frequencies that it did not affect the reliability of genotyping. We thus demonstrate that gene families with many co-amplifying genes can be reliably genotyped using HTS, provided that there is sufficient per amplicon coverage.

Ämnesord

NATURVETENSKAP  -- Biologi -- Genetik (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Genetics (hsv//eng)

Nyckelord

Amplicon sequencing
Bioinformatics
Copy number variation
Next-generation sequencing
Passerine MHC

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy