SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Oei Edwin H. G.))
 

Sökning: (WFRF:(Oei Edwin H. G.)) > Imaging-based asses...

Imaging-based assessment of fatty acid composition in human bone marrow adipose tissue at 7 T : Method comparison and in vivo feasibility

Emin, Sevgi (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Oei, Edwin H.G. (författare)
Erasmus University Medical Center
Englund, Martin (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,LU profilområde: Proaktivt åldrande,Lunds universitets profilområden,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,LU Profile Area: Proactive Ageing,Lund University Profile areas
visa fler...
Peterson, Pernilla (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,MR Physics,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
visa färre...
 (creator_code:org_t)
2023-02-27
2023
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 90:1, s. 240-249
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To demonstrate the feasibility and accuracy of chemical shift–encoded imaging of the fatty acid composition (FAC) of human bone marrow adipose tissue at 7 T, and to determine suitable image-acquisition parameters using simulations. Methods: The noise performance of FAC estimation was investigated using simulations with a range of inter-echo time, and accuracy was assessed using a phantom experiment. Furthermore, one knee of 8 knee-healthy subjects (ages 35–54 years) was imaged, and the fractions of saturated fatty acids (SFA) and polyunsaturated fatty acids (PUFA) were mapped. Values were compared between reconstruction methods, and between anatomical regions. Results: Based on simulations, ΔTE = 0.6 ms was chosen. The phantom experiment demonstrated high accuracy of especially SFA using a constrained reconstruction model (slope = 1.1, average bias = −0.2%). The lowest accuracy was seen for PUFA using a free model (slope = 2.0, average bias = 9.0%). For in vivo images, the constrained model resulted in lower intersubject variation compared with the free model (e.g., in the femoral shaft, the SFA percent-point range was within 1.0% [vs. 3.0%]). Furthermore, significant regional FAC differences were detected. For example, using the constrained approach, the femoral SFA in the medial condyle was lower compared with the shaft (median [range]: 27.9% [27.1%, 28.4%] vs. 32.5% [31.8%, 32.8%]). Conclusion: Bone marrow adipose tissue FAC quantification using chemical-shift encoding is feasible at 7 T. Both the noise performance and accuracy of the technique are superior using a constrained signal model.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

7 T
bone marrow adipose tissue
chemical shift–encoded imaging
fatty acid composition
MRI

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Emin, Sevgi
Oei, Edwin H.G.
Englund, Martin
Peterson, Pernil ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Magnetic Resonan ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy