SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Jakobsson Fredrik)
 

Search: WFRF:(Jakobsson Fredrik) > Adaptive spectral D...

Adaptive spectral Doppler estimation

Gran, Fredrik (author)
Jakobsson, Andreas (author)
Lund University,Lunds universitet,Biomedical Modelling and Computation,Forskargrupper vid Lunds universitet,Statistical Signal Processing Group,Matematisk statistik,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Lund University Research Groups,Mathematical Statistics,Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
Jensen, Jörgen (author)
 (creator_code:org_t)
2009
2009
English.
In: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - 0885-3010. ; 56:4, s. 700-714
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence. The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to provide good spectral resolution and contrast even when the observation window is very short. The 2 adaptive techniques are tested and compared with the averaged periodogram (Welch's method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set of matched filters (one for each velocity component of interest) and filtering the blood process over slow-time and averaging over depth to find the PSD. The methods are tested using various experiments and simulations. First, controlled flow-rig experiments with steady laminar flow are carried out. Simulations in Field II for pulsating flow resembling the femoral artery are also analyzed. The simulations are followed by in vivo measurement on the common carotid artery. In all simulations and experiments it was concluded that the adaptive methods display superior performance for short observation windows compared with the averaged periodogram. Computational costs and implementation details are also discussed.

Subject headings

NATURVETENSKAP  -- Matematik -- Sannolikhetsteori och statistik (hsv//swe)
NATURAL SCIENCES  -- Mathematics -- Probability Theory and Statistics (hsv//eng)

Keyword

common carotid artery
adaptive spectral estimation
spectral Doppler ultrasound
temporal resolution
data acquisition sequence
power spectral density
blood power spectral capon method
matched filters
blood amplitude and phase estimation technique
steady laminar flow
pulsating flow
femoral artery

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Gran, Fredrik
Jakobsson, Andre ...
Jensen, Jörgen
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Mathematics
and Probability Theo ...
Articles in the publication
IEEE Transaction ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view