SwePub
Sök i LIBRIS databas

  Utökad sökning

(AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Geriatrics)) srt2:(2000-2004)
 

Sökning: (AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Geriatrics)) srt2:(2000-2004) > A new tomographic t...

A new tomographic technique for absolute measurements of white and gray matter blood flow

Risberg, Jarl (författare)
Lund University,Lunds universitet,Institutionen för psykologi,Samhällsvetenskapliga institutioner och centrumbildningar,Samhällsvetenskapliga fakulteten,Department of Psychology,Departments of Administrative, Economic and Social Sciences,Faculty of Social Sciences
Börjesson, Siv (författare)
Lund University,Lunds universitet,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Ljunggren, Kaj (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
2003
2003
Engelska.
Ingår i: Journal of the International Neuropsychological Society. - 1355-6177. ; 9, s. 323-323
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The integrity of the white matter is as important as that of the gray matter and white matter pathology has commonly been reported in elderly subjects and in patients with organic dementia. The aim of the present study is to develop and evaluate an improved method for reliable tomographic measurements of absolute white and gray matter blood flow. The new tomographic method (modified Xe-SPECT) is based on an extension of the period of 133Xe inhalation from one to eight minutes followed by 22 instead of four minutes of breathing of ambient air. This gives a markedly enhanced signal from the white matter and better basis for correct quantification pf the blood flow. The arrival and clearance of the tracer are recorded by a three head gamma camera system that provides flow maps with a spatial resolution of about one cm. The new method has been evaluated in healthy younger and older (around 70 years) subjects as well as in a group of elderly patients with organic dementia. Our preliminary findings indicate that new and clinically valuable information is obtained by the improved Xe-SPECT method

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Psykiatri (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Psychiatry (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Geriatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Geriatrics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Risberg, Jarl
Börjesson, Siv
Ljunggren, Kaj
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Psykiatri
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Geriatrik
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Journal of the I ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy