Petersson, Kristoffer (författare)
Lausanne University Hospital
Kyroudi, Archonteia (författare)
Lausanne University Hospital
Bourhis, Jean (författare)
Lausanne University Hospital
visa fler...
Ceberg, Crister (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Radiotherapy Physics,Forskargrupper vid Lunds universitet,Rausinglaboratoriet i Lund - Tumörsektionen,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups,Rausing laboratory of Lund - Tumor section
Knoos, Tommy (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Radiotherapy Physics,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups
Bochud, Francois (författare)
Lausanne University Hospital
Möckli, Raphaël (författare)
Lausanne University Hospital
visa färre...
 (creator_code:org_t)
Elsevier BV, 2017
2017
Engelska.
Ingår i: Physics and imaging in radiation oncology. - : Elsevier BV. - 2405-6316. ; 3, s. 53-56
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We present a clinical distance measure for Pareto front evaluation studies in radiotherapy, which we show strongly correlates (r = 0.74 and 0.90) with clinical plan quality evaluation. For five prostate cases, sub-optimal treatment plans located at a clinical distance value of >0.32 (0.28–0.35) from fronts of Pareto optimal plans, were assessed to be of lower plan quality by our (12) observers (p < .05). In conclusion, the clinical distance measure can be used to determine if the difference between a front and a given plan (or between different fronts) corresponds to a clinically significant plan quality difference.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy