SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Figaji A)
 

Sökning: WFRF:(Figaji A) > Transcranial Dopple...

Transcranial Doppler pulsatility index is not a reliable indicator of intracranial pressure in children with severe traumatic brain injury

Figaji, Anthony A. (författare)
Zwane, Eugene (författare)
Fieggen, A. Graham (författare)
visa fler...
Siesjö, Peter (författare)
Lund University,Lunds universitet,Neurokirurgi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurosurgery,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Peter, Jonathan C. (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2009
2009
Engelska.
Ingår i: Surgical Neurology. - : Elsevier BV. - 0090-3019. ; 72:4, s. 389-394
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: The TCD-derived PI has been associated with ICP in adult studies but has not been well investigated in children. We examined the relationship between PI and ICP and CPP in children with severe TBI. Methods: Data were prospectively collected from consecutive TCD studies in children with severe TBI undergoing ICP monitoring. Ipsilateral ICP and CPP values were examined with Spearman correlation coefficient (mean values and raw observations), with a GEE, and as binary values (1 and 20 mm Hg, respectively). Results: Thirty-four children underwent 275 TCD studies. There was a weak relationship between mean values of ICP and PI (P = .04, r = 0.36), but not when raw observations (P = .54) or GEE (P = .23) were used. Pulsatility index was 0.76 when ICP was lower than 20 mm Hg and 0.86 when ICP was 20 mm Hg or higher. When PI was 1 or higher, ICP was lower than 20 mm Hg in 62.5% (25 of 40 studies), and when ICP was 20 mm Hg or higher, PI was lower than 1 in 75% (46 of 61 studies). The sensitivity and specificity of a PI threshold of 1 for examining the ICP threshold of 20 mm Hg were 25% and 88%, respectively. The relationship between CPP and PI was stronger (P = .001, r -0.41), but there were too few observations below 50 mm Hg to examine PI at this threshold. Conclusion: The absolute value of the PI is not a reliable noninvasive indicator of ICP in children with severe TBI. Further study is required to examine the relationship between PI and a CPP threshold of 50 mm Hg. (C) 2009 Elsevier Inc. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Children
pressure
Cerebral perfusion
Transcranial Doppler
Intracranial pressure
Traumatic brain injury
pulsatility index

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Figaji, Anthony ...
Zwane, Eugene
Fieggen, A. Grah ...
Siesjö, Peter
Peter, Jonathan ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Neurologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Surgical Neurolo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy