SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Rosén Ingmar)
 

Search: WFRF:(Rosén Ingmar) > (2015-2019) > Interobserver agree...

Interobserver agreement for neonatal seizure detection using multichannel EEG

Stevenson, Nathan J. (author)
Clancy, Robert R. (author)
Vanhatalo, Sampsa (author)
show more...
Rosén, Ingmar (author)
Lund University,Lunds universitet,Klinisk neurofysiologi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Neurophysiology,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Rennie, Janet M. (author)
Boylan, Geraldine B. (author)
show less...
 (creator_code:org_t)
2015-10
2015
English.
In: Annals of Clinical and Translational Neurology. - : Wiley. - 2328-9503. ; 2:11, s. 1002-1011
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective: To determine the interobserver agreement (IOA) of neonatal seizure detection using the gold standard of conventional, multichannel EEG. Methods: A cohort of full-term neonates at risk of acute encephalopathy was included in this prospective study. The EEG recordings of these neonates were independently reviewed for seizures by three international experts. The IOA was estimated using statistical measures including Fleiss' kappa and percentage agreement assessed over seizure events (event basis) and seizure duration (temporal basis). Results: A total of 4066 h of EEG recordings from 70 neonates were reviewed with an average of 2555 seizures detected. The IOA was high with temporal assessment resulting in a kappa of 0.827 (95% CI: 0.769-0.865; n = 70). The median agreement was 83.0% (interquartile range [IQR]: 76.6-89.5%; n = 33) for seizure and 99.7% (IQR: 98.9-99.8%; n = 70) for non-seizure EEG. Analysis of events showed a median agreement of 83.0% (IQR: 72.9-86.6%; n = 33) for seizures with 0.018 disagreements per hour (IQR: 0.000-0.090 per hour; n = 70). Observers were more likely to disagree when a seizure was less than 30 sec. Overall, 33 neonates were diagnosed with seizures and 28 neonates were not, by all three observers. Of the remaining nine neonates with contradictory EEG detections, seven presented with low total seizure burden. Interpretation: The IOA is high among experts for the detection of neonatal seizures using conventional, multichannel EEG. Agreement is reduced when seizures are rare or have short duration. These findings support EEG-based decision making in the neonatal intensive care unit, inform EEG interpretation guidelines, and provide benchmarks for seizure detection algorithms.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view