Ultrasound Doppler Vector Tomography - Measurements of Directional Blood Flow

Jansson, Tomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Medicinsk teknik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Biomedical Engineering, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Almqvist, Monica (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Stråhlén, Kent (författare)
visa fler...
Eriksson, Roger (författare)
Sparr, Gunnar (författare)
Lund University,Lunds universitet,Matematik LTH,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Mathematics (Faculty of Engineering),Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
Persson, Hans W (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Lindström, Kjell (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
1997
1997
Engelska.
Ingår i: Ultrasound in Medicine and Biology. - 0301-5629. ; 23:1, s. 47-57
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • An experimental system has been developed to verify the possibility of detecting flow activity using a technique called ultrasound Doppler vector tomography. A tomography algorithm is used to reconstruct blood flow vector fields using data from computer-controlled ultrasound continuous-wave Doppler scanning equipment. The result is a picture in which the brightness variations represent the reconstructed values of the curl of the velocity field (del x v). Continuous ultrasound is transmitted into a region with flow activity and the Doppler-shifted signals are received. To obtain measurement data suited for fan beam tomography, the scanning is performed in a plane from points encircling the region. Reconstructions have been achieved using measurement data from two different flow phantoms. A comparison between the experimental results and simulations shows good conformity. Copyright (C) 1997 World Federation for Ultrasound in Medicine & Biology.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

ultrasound
Doppler
tomography
blood flow
vector fields
continuous wave
vorticity
curl

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy