SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1745 3682
 

Sökning: L773:1745 3682 > (2020-2024) > Vitamin E infused h...

Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily : a randomized, controlled RSA trial with 5-year follow-up

Bergvinsson, Halldor (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Zampelis, Vasilis (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Forskningsgruppen för höft- och knäproteskirurgi,Forskargrupper vid Lunds universitet,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,The Hip and Knee Joint Arthroplasty Research Group,Lund University Research Groups,Skåne University Hospital
Sundberg, Martin (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Forskningsgruppen för höft- och knäproteskirurgi,Forskargrupper vid Lunds universitet,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,The Hip and Knee Joint Arthroplasty Research Group,Lund University Research Groups,Skåne University Hospital
visa fler...
Tjörnstrand, Jon (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Forskningsgruppen för höft- och knäproteskirurgi,Forskargrupper vid Lunds universitet,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,The Hip and Knee Joint Arthroplasty Research Group,Lund University Research Groups,Skåne University Hospital
Flivik, Gunnar (författare)
Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Forskningsgruppen för höft- och knäproteskirurgi,Forskargrupper vid Lunds universitet,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,The Hip and Knee Joint Arthroplasty Research Group,Lund University Research Groups,Skåne University Hospital
visa färre...
 (creator_code:org_t)
2022-01-20
2022
Engelska.
Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3682 .- 1745-3674. ; 93, s. 249-255
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and purpose - Vitamin E infused highly cross-linked polyethylene (VEPE) was introduced in order to enhance oxidative resistance in highly cross-linked polyethylene cups in total hip arthroplasty (THA). We have, with a follow-up of 5 years, evaluated wear characteristics of 2 identically designed cemented cups with the only difference being the material, VEPE or ultra-high molecular weight polyethylene (UHMWPE). Furthermore, we report cup migration and clinical outcome. Patients and methods - 48 patients with primary osteoarthritis were randomized to either UHMWPE or VEPE cups. Patients were followed with radiostereometric analysis (RSA) from the first postoperative day, at 3 months, 1, 2, and 5 years as well as with hip-specific outcome questionnaires. Results - At 3 months the mean proximal head penetration for UHMWPE was 0.07 mm (95% CI 0.03-0.11) and for VEPE 0.06 mm (-0.01 to 0.13). Thereafter, there was a continuous annual wear of 0.08 mm/year, up to 0.46 mm (0.36-0.57) at 5 years, for the UHMWPE cup. The VEPE cup showed low annual wear of 0.01 mm/year, up to 0.09 mm (0.02-0.16) at 5 years. In the first 3 months the UHMWPE cup migrated cranially 0.08 mm (0.03-0.13) whereas the VEPE cup migrated 0.17 mm (0.10-0.24), Thereafter, they showed similar migration patterns with stabilization between 2 and 5 years up to 0.21 mm (0.04-0.39) and 0.24 mm (0.13-0.36) respectively. The HOOS remained good up to 5 years, and no cup was revised. Interpretation - Compared with otherwise identical UHMWPE cups the cemented VEPE cup shows statistically significant reduction of wear up to 5 years and both cup types stabilize well with good clinical outcome.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bergvinsson, Hal ...
Zampelis, Vasili ...
Sundberg, Martin
Tjörnstrand, Jon
Flivik, Gunnar
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
Artiklar i publikationen
Acta Orthopaedic ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy