Primary Total Knee Arthroplasty Revised for Instability : A Detailed Registry Analysis
-
- Lewis, Peter L. (författare)
- Australian Orthopaedic Association National Joint Replacement Registry
-
Campbell, David G. (författare)
-
- Lorimer, Michelle F. (författare)
- South Australian Health and Medical Research Institute
-
visa fler...
-
Requicha, Francisco (författare)
-
- W-Dahl, Annette (författare)
- Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Robertsson, Otto (författare)
- Lund University,Lunds universitet,Ortopedi, Lund,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Orthopaedics (Lund),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2022
- 2022
- Engelska.
-
Ingår i: Journal of Arthroplasty. - : Elsevier BV. - 0883-5403. ; 37:2, s. 286-297
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: Instability after total knee arthroplasty is a common but poorly understood complication. Methods: Data from a large national registry was used to study patient and prosthesis characteristics of 2605 total knee arthroplasty revisions for instability. The cumulative percent revision was calculated using Kaplan-Meier estimates, and Cox proportional models used to compare revision rates. The rate of further revision was analyzed with regard to prostheses used in the first revision. Results: Instability increased from 6% of all first revision procedures in 2003 to 13% in 2019. The revision risk was lower for minimally stabilized prostheses, males, and patients aged ≥65 years. Polyethylene insert exchange was used for 55% of revision procedures, using a thicker insert in 93% and a change in insert conformity in 24% of cruciate-retaining knees. The increase in either thickness or conformity had no effect on the rate of further revision. After a revision for instability, 24% had a second revision by 14 years. Recurrent instability accounted for 32% of further revisions. A lower second revision rate was seen after revision of both femoral and tibial components, and where constrained components were used. Conclusion: Revision for instability is increasing. Revising both femoral and tibial components led to a lower rate of second revision compared to a change in insert alone. Recurrent instability was common.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
Nyckelord
- arthroplasty
- instability
- knee
- registry
- revision