A robust and fast method for arterial lumen diameter and intima-media thickness measurements

Erlöv, Tobias (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Segstedt, Simon (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Ahlgren, Asa Ryden (författare)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
visa fler...
Ricci, Stefano (författare)
University of Florence
Ostling, Gerd (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
Tortoli, Piero (författare)
University of Florence
Nilsson, Jan (författare)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
Jansson, Tomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Persson, Hans W (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Cinthio, Magnus (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2012
2012
Engelska.
Ingår i: 2012 IEEE International Ultrasonics Symposium (IUS). - 9781467345613 - 9781467345620 ; , s. 1678-1681
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Lumen diameter, distension and intima-media thickness (IMT) in human arteries are important parameters in cardiovascular research. The signal reflected from the arterial wall strongly depends on the ultrasound scanner and settings. The signal also varies with age and health of the subject. A general method insensitive with respect to the subject and the scanner would be of great help. We have developed a novel and robust method for ARTerIal Characterization (ARTIC), suitable for real-time in vivo measurements of diameter, distension and IMT using B-Mode images. The aim of this study was to evaluate ARTIC on different subjects and scanners. ARTIC was evaluated in vivo in different groups of subjects using two scanners, HDI5000 (Philips Medical Systems, Bothell, WA, USA) and ULA-OP (University of Florence, Italy). First, a comparison was made against a previous method validated on phantoms. Then measurements of young (healthy) and old (healthy and unhealthy) subjects were evaluated for both scanners. Finally, a comparison between scanners was made. The evaluation of different subjects shows a coefficient of variation (CV) ranging from 1.4-2.0% for diameter, 4.3-8.8% for distension and 3.6-6.6% for IMT.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

diameter
distension
intima-media thickness
carotid artery
non-invasive ultrasound
ULA-OP

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy