Contact dermatitis from glucose sensors in Spain : A multicentric approach

Gatica-Ortega, María Elena (författare)
Complejo Hospitalario de Toledo
Mowitz, Martin (författare)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups,Skåne University Hospital
Pastor-Nieto, María Antonia (författare)
University of Alcalá,Hospital Universitario de Guadalajara
visa fler...
Navarro-Triviño, Francisco J. (författare)
Hospital Clínico Universitario San Cecilio
Fernández-Redondo, Virginia (författare)
Complejo Hospitalario Universitario de Santiago
Hernández-Cano, Natalia (författare)
University Hospital La Paz
Borrego, Leopoldo (författare)
University of Las Palmas de Gran Canaria
Gómez-de-la-Fuente, Enrique (författare)
Hospital Universitario Fundación Alcorcón
Torralba, Miguel (författare)
Hospital Universitario de Guadalajara,University of Alcalá
Svedman, Cecilia (författare)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups,Skåne University Hospital
Giménez-Arnau, Ana (författare)
Autonomous University of Barcelona
visa färre...
 (creator_code:org_t)
2021-08-25
2021
Engelska.
Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 85:5, s. 554-562
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Allergic contact dermatitis from glucose sensors may interfere with their ongoing application. Objective: To evaluate a series of Spanish patients with contact dermatitis to glucose sensors regarding former sources of contact allergens, patch test results, and outcomes from the ongoing use of the device. Methods: A series of patients with contact dermatitis from glucose sensors was investigated in eight dermatology departments across Spain (epidemiological features, brands, latency time to develop dermatitis, the ability to continue using the devices as well as the patch test results). Results: Thirty patients were evaluated (mean age 20.9 years). A total of 66.7% were children and 66.7% female. Ninety per cent used Freestyle Libre (FSL). Eight of 26 (30.8%) reacted to isobornyl acrylate (IBOA) and two of 20 (10.0%) to N,N dimethylacrylamide (DMAA). The mean latency time to develop dermatitis was 9 months. Sixteen of 29 (55.2%) patients continued using the same sensor causing the reaction. Thirteen of 29 (44.8%) patients were unable to continue using the sensor because of severe reactions. Of these, five were positive to IBOA, one to IBOA and DMAA, one to DMAA, one to colophony, and one to isopropyl alcohol wipes. In one patient, the outcome was unknown. Conclusion: The frequency of sensitisation to IBOA and DMAA, was lower than in other European series, but similar to a previously published Spanish article. Legislation requiring manufacturers to provide information regarding the composition of medical devices and cooperate with the investigations into contact dermatitis is urgently needed.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Dermatologi och venereologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dermatology and Venereal Diseases (hsv//eng)

Nyckelord

acrylates
adhesives
allergic contact dermatitis
glucose sensor
glucose sensor sets
insulin pump
isobornyl acrylate (CAS 5888-33-5)
medical devices
N,N dimethylacrylamide (CAS no. 2680-03-7)
patch test

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy