SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Dustler Magnus)
 

Search: WFRF:(Dustler Magnus) > Monte Carlo simulat...

Monte Carlo simulation of breast tomosynthesis: visibility of microcalcifications at different acquisition schemes

Petersson, Hannie (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Dustler, Magnus (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Tingberg, Anders (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
show more...
Timberg, Pontus (author)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
show less...
 (creator_code:org_t)
SPIE, 2015
2015
English.
In: Medical Imaging 2015: Physics of Medical Imaging. - : SPIE. - 0277-786X .- 1996-756X. ; 9412, s. 94121-94121
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Microcalcifications are one feature of interest in mammography and breast tomosynthesis (BT). To achieve optimal conditions for detection of microcalcifications in BT imaging, different acquisition geometries should be evaluated. The purpose of this work was to investigate the influence of acquisition schemes with different angular ranges, projection distributions and dose distributions on the visibility of microcalcifications in reconstructed BT volumes. Microcalcifications were inserted randomly in a high resolution software phantom and a simulation procedure was used to model a MAMMOMAT Inspiration BT system. The simulation procedure was based on analytical ray tracing to produce primary images, Monte Carlo to simulate scatter contributions and flatfield image acquisitions to model system characteristics. Image volumes were reconstructed using the novel method super-resolution reconstruction with statistical artifact reduction (SRSAR). For comparison purposes, the volume of the standard acquisition scheme (50 degrees angular range and uniform projection and dose distribution) was also reconstructed using standard filtered backprojection (FBP). To compare the visibility and depth resolution of the microcalcifications, signal difference to noise ratio (SDNR) and artifact spread function width (ASFW) were calculated. The acquisition schemes with very high central dose yielded significantly lower SDNR than the schemes with more uniform dose distributions. The ASFW was found to decrease (meaning an increase in depth resolution) with wider angular range. In conclusion, none of the evaluated acquisition schemes were found to yield higher SDNR or depth resolution for the simulated microcalcifications than the standard acquisition scheme.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

breast tomosynthesis
Monte Carlo simulation
acquisition parameters
software breast phantom
microcalcification simulation

Publication and Content Type

kon (subject category)
ref (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Petersson, Hanni ...
Dustler, Magnus
Tingberg, Anders
Timberg, Pontus
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Medical Imaging ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view