SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sörnmo Leif)
 

Sökning: WFRF:(Sörnmo Leif) > Application of freq...

Application of frequency and sample entropy to discriminate long-term recordings of paroxysmal and persistent atrial fibrillation

Alcaraz Martinez, Raul (författare)
Sandberg, Frida (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
Sörnmo, Leif (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Rieta, José Joaquín (författare)
visa färre...
 (creator_code:org_t)
2010
2010
Engelska.
Ingår i: Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE. - 1557-170X. - 9781424441235 ; , s. 4558-4561
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Atrial fibrillation (AF) is the most common arrhythmia in clinical practice. At an early stage of the disease, AF may terminate spontaneously and is then referred to as paroxysmal AF. On the other hand, when external intervention is required for the arrhythmia to terminate, it is referred to as persistent AF. In this work, a method to discriminate between paroxysmal and persistent AF in the long-term ECGs is presented. The dominant frequency as well as the organization of the atrial activity are employed to characterize AF. The dominant atrial frequency (DAF) is estimated using hidden Markov model based frequency tracking, and organization is estimated by the sample entropy of the main atrial wave (MAW) and the first two harmonics, respectively. Long-term variations in DAF and organization from 50 ECG recordings were evaluated, showing that episodes of paroxysmal AF were consistently associated with lower DAF and organization of the MAW and the harmonics, than was persistent AF. Discrimination of paroxysmal and persistent AF resulted in classification rates of 84.1±26.1%, thus suggesting that it possible to discriminate between paroxysmal and persistent AF in patients without previously known AF history.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

diseases
electrocardiography
hidden Markov models
physiological models
ECG
arrhythmia
atrial fibrillation
dominant atrial frequency
entropy
main atrial wave

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Alcaraz Martinez ...
Sandberg, Frida
Sörnmo, Leif
Rieta, José Joaq ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
Artiklar i publikationen
Engineering in M ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy