SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Davidsson Richard)
 

Sökning: WFRF:(Davidsson Richard) > Harmful azo coloran...

Harmful azo colorants in leather. Determination based on their cleavage and extraction of corresponding carcinogenic aromatic amines using modern extraction techniques.

Sparr Eskilsson, Cecilia (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Davidsson, Richard (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Mathiasson, Lennart (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2002
2002
Engelska.
Ingår i: Journal of Chromatography A. - 0021-9673. ; 955:2, s. 215-227
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study concerns the possibilities of using microwave-assisted extraction (MAE) or supercritical fluid extraction (SFE) for detection of harmful azo colorants in leather. After degreasing of the leather sample with SFE there follows a reductive cleavage of the azo colorants to their corresponding aromatic amines in the MAE or SFE equipment. The aromatic amines are subsequently extracted using either MAE or SFE and then finally determined by liquid chromatography with diode-array detection. The results have been compared with recoveries obtained using the German DIN method 53316. This standard method, based on conventional solvent extraction, is used in several European countries. Overall much better recoveries were obtained using MAE or SFE. With both MAE and SFE the amine recoveries of spiked leather samples were generally above 50%. The average recoveries were 62% for MAE and 60% for SFE (solvent collection) compared to 24% with the DIN method. For genuine leather samples the recoveries decreased, especially for benzidine. In this case the average values for MAE, SFE and DIN were 54, 38 and 19%, respectively. The quantification limits in leather samples using MAE or SFE were below 1 mg/kg for all amines investigated. The within-laboratory precision was generally better than 10%, varying somewhat with the analyte considered. With the proposed methodology, the amount of hazardous organic solvents used could be decreased and the sample throughput increased with at least a factor of two with less manual handling compared to the DIN method.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Azo dyes
aromatic
Amines

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sparr Eskilsson, ...
Davidsson, Richa ...
Mathiasson, Lenn ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Journal of Chrom ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy