SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sörnmo Leif)
 

Sökning: WFRF:(Sörnmo Leif) > (2015-2019) > A novel statistical...

A novel statistical model of the dual pathway atrioventricular node during atrial fibrillation

Henriksson, Mikael (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Corino, Valentina D A (författare)
Polytechnic University of Milan
Sörnmo, Leif (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Sandberg, Frida (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2016
2016
Engelska 4 s.
Ingår i: Computing in Cardiology. - 9781509006854 ; 42, s. 473-476
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The atrioventricular (AV) node plays an important role during atrial fibrillation (AF). In particular, the refractoriness of its cells influences the conduction of atrial impulses to the ventricles and, thus, the ventricular response. This study introduces a novel statistical model of the AV node, accounting for pathway switching, which can be used for non-invasive assessment of the refractory properties of the slow and the fast AV nodal pathway during AF, using the atrial fibrillatory rate and the series of RR intervals obtained from the ECG. A number of simulated histograms is presented, illustrating that even though only four parameters are used to characterize the AV node, the model is capable of representing a wide range of different RR interval series. Estimation of model parameters is evaluated with simulated RR interval series. It is shown that a signal consisting of 2400 RR intervals is sufficient for accurate parameter estimation, with an average estimation error less than 50 ms in all parameters. It is concluded that the model offers a novel way to obtain information regarding AV nodal refractoriness from the ECG.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Annan medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Other Medical Biotechnology (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Henriksson, Mika ...
Corino, Valentin ...
Sörnmo, Leif
Sandberg, Frida
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinsk biotek ...
och Annan medicinsk ...
Artiklar i publikationen
Computing in Car ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy