Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: a monte Carlo study

Ljungberg, Michael (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Strand, Sven-Erik (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
1991
1991
Engelska.
Ingår i: Journal of Nuclear Medicine. - 0161-5505. ; 32:6, s. 1278-1284
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Single-photon emission computed tomography (SPECT) is important for imaging radioactivity distributions in vivo. Quantitative SPECT is limited due to attenuation and scatter contribution. Approximations such as constant attenuation and mono-exponential scatter functions will not be valid for non-homogeneous regions. A correction method is described where non-uniform density-maps are used in the attenuation correction. Correction for non-uniform scatter is made by a convolution technique based on scatter line-spread functions (SLSF) calculated for different locations inside a clinically realistic, nonhomogeneous, computer phantom. Calculations have been made for a myocardiac source, a uniform source in the lungs and a tumor located in the lungs. Projections were simulated for photon energies corresponding to 201Tl, 99mTc, and 111In. The results show that quantitative images can be obtained in nonhomogeneous regions. An increased contrast has also been demonstrated in the SLSF-corrected images. Comparison with measurements have been made to validate the Monte Carlo code and the scatter and attenuation method.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ljungberg, Micha ...
Strand, Sven-Eri ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Journal of Nucle ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy