SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0021 8502
 

Sökning: L773:0021 8502 > Methods to measure ...

  • Karlsson, MartinLund University,Lunds universitet,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Physics,Departments at LTH,Faculty of Engineering, LTH (författare)

Methods to measure and predict the transfer function size dependence of individual DMAs

  • Artikel/kapitelEngelska2003

Förlag, utgivningsår, omfång ...

  • 2003

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:cf55bb22-fa6f-4f25-936d-5e7f01e854fb
  • https://lup.lub.lu.se/record/310455URI
  • https://doi.org/10.1016/S0021-8502(03)00020-XDOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • In this study of the transfer function of copies of the Vienna-type differential mobility analyser (DMA) it was found that three, supposedly identical, DMAs exhibited distinct differences with respect to the width of the transfer function. This means that the transfer function of a DMA needs to be determined on an individual basis in order to obtain accurate results from DMA measurements. The size dependence of the transfer function width and the penetration of three DMAs were investigated experimentally in a broad range of Peclet numbers (400-400000). Two of the three DMAs exhibited transfer function widths in excess of the broadening induced by diffusion. The size dependence of the width of all three DMAs could be explained within a few percents by assuming an instrument-specific, size-independent broadening in addition to diffusion broadening. The penetration was evaluated by relating to deposition in a circular tube. Excellent agreement between the experimental data and the simple model was obtained. The penetration study was extended to include literature data, showing that the simple model could be applied and that there are distinct differences between different DMA types. The results of this study indicate that the size dependence of the width of the transfer function and the penetration can be estimated by measuring the transfer function for a single particle size, thus greatly reducing the amount of work required by DMA users to characterise their instruments. (C) 2003 Elsevier Science Ltd. All rights reserved.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Martinsson, BengtLund University,Lunds universitet,Kärnfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Nuclear physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)nucl-bma (författare)
  • Fysiska institutionenInstitutioner vid LTH (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Aerosol Science34:5, s. 603-6250021-8502

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Karlsson, Martin
Martinsson, Beng ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Subatomär fysik
Artiklar i publikationen
Journal of Aeros ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy