SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1532 2092 OR L773:1099 5129
 

Sökning: L773:1532 2092 OR L773:1099 5129 > (2000-2004) > Detection of inter-...

Detection of inter-atrial conduction defects with unfiltered signal-averaged P-wave ECG in patients with lone atrial fibrillation

Platonov, Pyotr (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Carlson, Jonas (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Ingemansson, Max (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Roijer, Anders (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Hansson, A (författare)
Chireikin, L V (författare)
Olsson, Bertil (författare)
Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2000-01-01
2000
Engelska.
Ingår i: Europace. - : Oxford University Press (OUP). - 1532-2092. ; 2:1, s. 32-41
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIMS: To demonstrate a possible inter-atrial conduction delay in patients with lone paroxysmal atrial fibrillation (PAF) using 'unfiltered' signal-averaged P-wave ECG (PSAECG) and compare these results with those obtained with conventional filter settings. METHODS AND RESULTS: Twenty one patients with lone PAF and 20 healthy volunteers (control group) were enrolled in the study. An orthogonal lead surface ECG was high-pass filtered at 0.8 Hz, averaged with template matching, and combined into a spatial magnitude ('unfiltered' technique). Results were compared with conventionally filtered (40-300 Hz) PSAECG. The filtered technique revealed no differences in P-wave duration between the two groups (121 +/- 12 vs 128 +/- 15 ms, control and PAF groups respectively, ns). Double-peaked P-wave spatial magnitudes (interpeak distance >30 ms) were revealed in 11 of 21 PAF patients but only in two of 18 controls (P<0.01). The nadir in the spatial magnitude was located significantly later in the PAF group (114 +/- 13 vs 103 +/- 9 ms, P<0.01). CONCLUSION: 'Unfiltered' PSAECG revealed significant differences in orthogonal P-wave morphology in patients with lone PAF, indicating the possibility of an inter-atrial conduction delay, while conventional P-wave duration analysis failed to discriminate between the two groups.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Signal-averaged P-wave ECG
paroxysmal atrial fibrillation
inter-atrial conduction

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Europace (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy