Sökning: L773:1532 2092 OR L773:1099 5129
> (2000-2004) >
Detection of inter-...
Detection of inter-atrial conduction defects with unfiltered signal-averaged P-wave ECG in patients with lone atrial fibrillation
-
- Platonov, Pyotr (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Carlson, Jonas (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Ingemansson, Max (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa fler...
-
- Roijer, Anders (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
Hansson, A (författare)
-
Chireikin, L V (författare)
-
- Olsson, Bertil (författare)
- Lund University,Lunds universitet,Kardiologi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Cardiology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- 2000-01-01
- 2000
- Engelska.
-
Ingår i: Europace. - : Oxford University Press (OUP). - 1532-2092. ; 2:1, s. 32-41
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://academic.oup...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- AIMS: To demonstrate a possible inter-atrial conduction delay in patients with lone paroxysmal atrial fibrillation (PAF) using 'unfiltered' signal-averaged P-wave ECG (PSAECG) and compare these results with those obtained with conventional filter settings. METHODS AND RESULTS: Twenty one patients with lone PAF and 20 healthy volunteers (control group) were enrolled in the study. An orthogonal lead surface ECG was high-pass filtered at 0.8 Hz, averaged with template matching, and combined into a spatial magnitude ('unfiltered' technique). Results were compared with conventionally filtered (40-300 Hz) PSAECG. The filtered technique revealed no differences in P-wave duration between the two groups (121 +/- 12 vs 128 +/- 15 ms, control and PAF groups respectively, ns). Double-peaked P-wave spatial magnitudes (interpeak distance >30 ms) were revealed in 11 of 21 PAF patients but only in two of 18 controls (P<0.01). The nadir in the spatial magnitude was located significantly later in the PAF group (114 +/- 13 vs 103 +/- 9 ms, P<0.01). CONCLUSION: 'Unfiltered' PSAECG revealed significant differences in orthogonal P-wave morphology in patients with lone PAF, indicating the possibility of an inter-atrial conduction delay, while conventional P-wave duration analysis failed to discriminate between the two groups.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- Signal-averaged P-wave ECG
- paroxysmal atrial fibrillation
- inter-atrial conduction