SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Andersson Sören)
 

Search: WFRF:(Andersson Sören) > IDAC-CAD2VOX : A so...

IDAC-CAD2VOX : A software for radiation protection calculations for the ICRP reference phantoms which are in an environment described by detailed cad drawings

Andersson, Martin (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Herrnsdorf, Lars (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Mattsson, Sören (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
 (creator_code:org_t)
2017
2017
English 4 s.
In: Medical Physics in the Baltic States : Proceedings of the 13th International Conference on Medical Physics. ; , s. 10-13
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • A computer program called IDAC-CAD2VOX has been constructed to create geometry input files from CAD drawings for the Monte Carlo simulation program MCNP. The ICRP reference phantoms are incorporated into the CAD drawings to estimate organ doses and the effective dose. The program is applied to a CAD drawing of a house and a 2D drawing of a radiation protection bunker. The created MCNP geometry was visualised by an external program Visual Editor. Dose calculations were performed for a CAD -drawing of a house, where a point source of 1 GBq 99mTc was placed in the attic. The effective dose to the adult male ICRP reference phantom was estimated to be 7.0 µSv when placed in the living room on the second floor. In summary, a method has been developed to enable effective dose estimations to adults directly from CAD files and to present the results in a pedagogic and easily understandable way.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

CAD
Monte Carlo simulations
ICRP reference phantoms
Effective dose
IDAC

Publication and Content Type

kon (subject category)
ref (subject category)

To the university's database

Find more in SwePub

By the author/editor
Andersson, Marti ...
Herrnsdorf, Lars
Mattsson, Sören
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view