Search: (L773:0278 6826 OR L773:1521 7388) >
Experimental eviden...
Experimental evidence for evaporation/condensation nonuniform flow in a horizontal aerosol generator
-
Damour, T M (author)
-
Ehrman, S H (author)
-
- Karlsson, Martin (author)
- Lund University,Lunds universitet,Fasta tillståndets fysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Solid State Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
show more...
-
- Karlsson, Lisa (author)
- Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
- Deppert, Knut (author)
- Lund University,Lunds universitet,Fasta tillståndets fysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Solid State Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
-
show less...
-
(creator_code:org_t)
- Informa UK Limited, 2005
- 2005
- English.
-
In: Aerosol Science and Technology. - : Informa UK Limited. - 1521-7388 .- 0278-6826. ; 39:5, s. 444-451
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- The formation of deposition patterns in the cooling zone during operation of a horizontal evaporation/condensation nanoparticle generator was studied to obtain information about flow conditions during particle formation. Quartz reactor tubes were used together with a simple light attenuation measurement to characterize deposition as a function of axial location. Results for the onset and pattern of deposition for four different metals-indium, gallium, silver, and lead-were obtained, and size distributions for indium and gallium particle nanoparticles at different temperatures were measured. Distinct deposition bands could be observed resulting from vapor deposition, nanioparticle deposition, or a combination of both. The location or the bands varied with metal and evaporation temperature. Experimentally observed fluctuations in temperature, bimodal size distributions obtained at the highest furnace temperatures, as well as asymmetric deposition patterns suggested the How in the cooling portion of the generator is nonuniform, possibly as a result of buoyancy. These results are important for the design of nanoparticle generation systems, in that horizontal evaporation/condensation generators are often chosen on the basis of assumed simplicity with respect to flow, and this may not always be the case.
Subject headings
- NATURVETENSKAP -- Kemi -- Fysikalisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Physical Chemistry (hsv//eng)
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
To the university's database